Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

Error
Code
Description
1
Flash Program CRC Error
2
Flash Template CRC Error
3
Reserved
4
Reserved
5
RAM Error Log CRC Error
6
RAM Function Programming
CRC Error
7
RAM Unit Prices CRC Error
8
RAM Statistics CRC Error
9
RAM Event Logs CRC Error
10
RAM Totals CRC Error
11
RAM Totalizers CRC Error
12
RAM Electro-mech Totalizers
CRC Error
13
Reserved
14
Reserved
15
Reserved
16
Suppress Overflow Limit
Reached - Function 19.12-.22
17
Reserved
18
Reserved
19
Reserved
20
n Consecutive Display Read
Back Error -
Device #s: 0 = Sales, 1 = Unit
Price, 2 = Preset
64

Part No. 920525 Rev A

TABLE 6-1. ERROR CODES AND SOLUTIONS
Probable Cause
Corrupt Flash Program Area
Corrupt Or Incompatible Flash
Template Area
Corrupt RAM Error Log Data
Corrupt RAM Function Data
Corrupt RAM Unit Price Data
Corrupt RAM Statistics Data
Corrupt RAM Event Log Data
Corrupt RAM Totals Data
Corrupt RAM Totalizer Data
Corrupt RAM EMT Data
Slow down limit too low
Defective flow control valve
Defective display board or cable
Defective preset board or cable
Defective computer base
Corrective Action
Bootstrap & Re-Flash Program
or Replace computer base
Download correct template
Replace computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Re-Flash Program or Replace
computer base
Adjust slow down volume -
(Dispenser or POS)
Replace valve
Replace display board or cable
Replace preset board of cable
Re-Flash Program & Template
or Replace computer base
June 2001

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents