Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

F96 - Upload Flash Memory Programming
This function requires the service terminal, NOT the remote control.
This function has no subfunctions. Press ENTER to transmit the FLASH program data. The service terminal program
requests a filename to upload the data to. Select the file to begin the program upload.
When the FLASH program upload finishes, the computer goes back to function entry mode where you may access
other functions.
F97 - Upload Dispenser Configuration Templates
This function requires the service terminal, NOT the remote control.
This function has no subfunctions. Press ENTER to transmit the FLASH template data. The service terminal
program requests a filename to upload the data to. Select the file to begin the template upload.
When the FLASH template upload is complete, the computer will go back to function entry mode where you can
access other functions.
F98 - Download Flash Memory Programming
This function requires the service terminal, NOT the remote control.
This function has no subfunctions. Complete the following steps to use the service terminal:
1.
Enter PASS 1.
2.
Enter PASS 2.
3.
Enter Function.
4.
Enter Verification Code.
5.
Select the file.
The service terminal program requests a filename to download. You can browse various directories for the desired
file. Select the correct file to start the program download. If you cannot find the file or if the there is a bad CRC, the
download aborts.
It is important that you do not interrupt the download for any reason. If this happens, you will have to load the
FLASH via bootstrap mode. See the procedure on the following page for a description of the bootstrap mode.
When the download is complete, the software executes a warm start which is just like a power cycle. If the laptop is
still connected and the laptop program is still running, the computer will re-enter maintenance mode prompting for
the passwords to be entered. At this point you can terminate the laptop program and disconnect the laptop.
The FLASH memory programming that is being downloaded contains a default template. If the template that is
currently in the FLASH is compatible with the new version of program code, the template data is preserved. If the
template data that is currently in the flash is not compatible with the new version of program code, the template data
will be overwritten with the default template.
.
F99 - Download dispenser Configuration Template
This function has no subfunctions. Press ENTER to download a verification code and display the word PASS. Enter
42 for the verification code. The program on the laptop requests a filename to download. You can browse various
directories for the desired file. Select the correct file to start the program download. If you cannot find the file or if the
there is a bad CRC, the download aborts.
If the template download is interrupted, restart the service terminal and reload the template.
54

Part No. 920525 Rev A

June 2001

Hide quick links:

Advertisement

Table of Contents
loading