Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

45
Reserved
46
Vapor Recovery Motor Turning
Wrong Direction
47
Illegal Sensor States from Vapor
Recovery Sys
48
Vapor Recovery Motor Load
High
49
Vapor Recovery Motor Load
Low
50
Jitter Limit Reached on an In
Transaction Pulser
51
Jitter Limit Reached on an Idle
Pulser
52
Jitter Limit Reached on an
Illegal Pulser
53
Reserved
54
Reserved
55
Reverse Flow Limit Reached on
an Illegal Pulser
56
Forward Flow Limit Reached on
an Idle Pulser
57
Forward Flow Limit Reached on
an Illegal Pulser
58
Communications Lost to an In
Transaction Pulser
59
Communications Lost to an Idle
Pulser
60
Reserved
61
Reserved
62
Pulser is Outputting Jitter
63
Reserved
64
Reserved
65
Reserved
66
Reserved
66

Part No. 920525 Rev A

Defective Wayne Vac Motor or
cables
Defective Wayne Vac control board
Defective Wayne Vac Motor or
cables
Defective Wayne Vac control board
Defective Wayne Vac Motor
Blocked vapor path
Defective Wayne Vac Motor
Defective Pulser
Defective Pulser
Defective Pulser
Defective check valve
Defective flow control valve
Defective computer
Defective Pulser
Defective ISB or cables
Defective Pulser
Defective ISB or cables
Volume of fuel dispensed during a
meter calibration exceeded limits.
Defective Pulser
Replace
Replace
Replace
Replace
Replace Wayne Vac Motor
Check vapor return path
(nozzle, hose, breakaway)
Check for vein adjustments
and debris.
Replace Motor
Replace
Replace
Replace
Replace
Replace
Re-Flash Program & Template
or Replace computer base
Replace
Replace
Replace
Replace
----
Replace Pulser
June 2001

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents