6.2
SUB ENTRY LEVEL
When you enter the sub entry level, the unit price display shows the function/statistic number in the two left-most
digits and the sub level number in the two right-most digits separated with a decimal point. The F or S no longer
appear. The following list shows functionality provided at this level. Not all functionality is available depending on
user access.
NEXT
Advances to the next sub function or sub-statistic within the current function or statistic.
If you enter numeric data without first pressing the # key, the system goes to the sub function or sub-statistic of the
corresponding number that you entered. If the number is beyond the range of available subfunctions or substatistics,
the maximum sub function or sub-statistic is used.
When you begin to enter numbers (preceded by the # key or not), the non-numeric keys have the following
functionality.
CLEAR
Backspace key if there is numeric input, otherwise returns control to initial screen.
ENTER
Accepts any numeric input already entered.
UP
Ignored when numeric input has been entered, otherwise returns control to the sub entry level.
DOWN
Ignored when numeric input has been entered, otherwise returns control to the sub entry level.
#
Ignored when numeric input has been entered, otherwise returns control to sub entry level.
NEXT
Ignored when numeric input has been entered, otherwise returns control to the sub entry level.
6.3
FUNCTION LIST
The template controls access to functions and subfunctions. The template contains an access level table that
determines what functions each user has access to. Access levels are as follows:
l
Read and Write
l
Read only
l
No access
F00 - Exit Function
Use this function to select one of three maintenance mode exits.
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Exit Option, 1 through 3
1 = Do not exit and do not save changes
2 = Exit, but do not save changes
3 = Exit and save changes
June 2001
43

Part No. 920525 Rev A