Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

F25 - Local Preset By Button Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Preset button #1 operation mode
1 = Money
2 = Volume
.01
Preset button #2 operation mode
1 = Money
2 = Volume
.02
Preset button #3 operation mode
1 = Money
2 = Volume
.03
Preset button #1 money/volume limit, 0-999999
.04
Preset button #2 money/volume limit, 0-999999
.05
Preset button #3 money/volume limit, 0-999999
F26 - VAP Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
ORVR control
1 = Enabled
2 = Disabled
F27 - Side A Dispenser Configuration
.00
Button input for Local Authorize function, 0-8, where 0 = not supported
F28 - Side B Dispenser Configuration
.00
Button input for Local Authorize function, 0-8, where 0 = not supported
F29 - Side A Liter Flow Rate Configuration
.0N
Maximum slow flow rate, 3-50 (units of 1/10 Liters/min.)
.1N
Minimum slow flow rate, 0-50 (units of 1/10 Liters/min.), 0 = no minimum
.2N
Maximum fast flow rate, 10-180 (units of Liters/min.)
.3N
Minimum fast flow rate, 0-180 (units of Liters/min.), 0 = no minimum
N
Logical nozzle
F30 - Side B Liter Flow Rate Configuration
.0N
Maximum slow flow rate, 3-50 (units of 1/10 Liters/min.)
.1N
Minimum slow flow rate, 0-50 (units of 1/10 Liters/min.), 0 = no minimum
.2N
Maximum fast flow rate, 10-180 (units of Liters/min.)
.3N
Minimum fast flow rate, 0-180 (units of Liters/min.), 0 = no minimum
N
Logical nozzle
F31 - Side A Gallon Flow Rate Configuration
.0N
Maximum slow flow rate, 1-10 (units of 1/10 Gallons/min.)
.1N
Minimum slow flow rate, 0-10 (units of 1/10 Gallons/min.), 0 = no minimum
June 2001
51

Part No. 920525 Rev A