Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

l
The money display contains the current counter value showing how many times this products blend ratio has
changed.
l
The volume display contains the current blend ratio
If you press one of the following keys while you are in this mode, the corresponding action occurs:
CLEAR
The system enters the View Volume Metering Unit Change Counters mode.
ENTER
The system enters the View Blend Ratio Change Event Logs mode.
NEXT
The next products change counter data in the sequence is displayed, unless you are viewing the last
products change counter. Otherwise the system enters the View Volume Metering Unit Change
Counters mode.
0.1.3
View Blend Ratio Change Event Logs Mode
In this mode, the following sequence repeats every 20 seconds for the last ten event logs for the selected product.
When all ten event logs are finished displaying, control returns to the previous mode.
The corresponding unit price display contains bC n where n is the blend change event number (1-10) where 1 is the
last blend change event and 10 is the oldest stored change event.
The sale display alternates every two seconds between the following pages:
The money display displays either LOCAL or SErIAL depending on whether the blend ratio change came from
local programming or from the serial link to the site controller and the volume display contains the blend ratio that it
was changed to with this event.
The money display contains the date of the event in the form of mm.dd.yy where "mm" is the month, "dd" is the day,
"yy" is the year. The volume display contains the time of the event in the form of hh.mm where hh is the hour (0-23)
and mm is the minute (0-59).
If you press one of the following keys while in this mode, the corresponding action is taken:
CLEAR
The system exits the View Blend Ratio Change Event Logs mode and returns control to the View
Blend Ratio Change Counters log.
ENTER
The system exits the View Blend Ratio Change Event Logs mode and returns control to the View
Blend Ratio Change Counters log.
NEXT
The next blend change event displays. If you are viewing event 10, it will wrap around and show
event 1.
UP
The next blend change event displays. If you are viewing event 10, it will wrap around and show
event 1.
DOWN
The previous blend change event displays. If you are viewing event 10, it will wrap around and
show event 1.
0.1.4
View Volume Metering Unit Change Counters Mode
In this mode, the following items display for 20 seconds
1.
Unit price displays contain Unit (for volume metering unit)
2.
Money price display contains the current counter value showing how many times the volume metering unit was
displayed
3.
Volume display contains the current volume metering unit described as follows:
June 2001