Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

.2N
Maximum fast flow rate, 3-48 (units of Gallons/min.)
.3N
Minimum fast flow rate, 03-48 (units of Gallons/min.), 0 = no minimum
N
Logical nozzle
F32 - Side B Gallon Flow Rate Configuration
.0N
Maximum slow flow rate, 1-10 (units of 1/10 Gallons/min.)
.1N
Minimum slow flow rate, 0-10 (units of 1/10 Gallons/min.), 0 = no minimum
.2N
Maximum fast flow rate, 3-48 (units of Gallons/min.)
.3N
Minimum fast flow rate, 03-48 (units of Gallons/min.), 0 = no minimum
N
Logical nozzle
F33 - Password Change
Dashes appear in the money display window, and the word PASS appears on the volume display. When you begin
editing, the money display goes blank and dashes appear instead of the regular entries. Enter the new password twice.
The sub-function numbers are defined as follows:
.00
Service Engineer Password, maximum of 6 characters (Use numbers only)
.01
Station Manager Password, maximum of 6 characters (Use numbers only)
.02
Station Operator Password, maximum of 6 characters (Use numbers only)
.03
Weights and Measures Password, maximum of 6 characters (Use numbers only)
F34 - Diagnostics
These functions provide a way to test various parts of the hardware, including all switches, displays, beeper and
Vapor recovery. Other motors and valves are not available for security and safely reasons. When a test is invoked,
press CLEAR or ENTER to end the test.
.01
Switch test. The money display shows 4 dashes until a switch is activated. A description of the activated
switch and side (1 or 2) is displayed on the money display. For example, nozzle switch 3 on side 2 is
displayed as 2n3 as long as the switch is depressed (n=nozzle, S=Stop switch, b = bitbus, P = preset). When
the nozzle is deactivated the display reverts to dashes.
.02
Display test. A "walking segment" test is performed in which each segment of the display is turned on and
off. Each digit of the display is tested at the same time.
.03
Vapor Recovery subsystem test, Side A
.04
Vapor Recovery subsystem test, Side B
These subfunctions simulate a flow rate to the vapor recovery system, which turns on the recovery motor
accordingly. At least one nozzle on the specified side must have WayneVac enabled for the motor to turn on.
The volume display shows the simulated flowrate. The money display shows actual RPM as measured by
the computer. The UP key increases the simulated flowrate. The DOWN key decreases the flowrate.
Simulated flow rates:
Off
Low (7.0 GPM)
Medium (8.5 GPM)
High (10.0 GPM)
52

Part No. 920525 Rev A

June 2001