Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

.06
Suppress display of leading zeros in normal mode
1 = Yes
2 = No
.07
Totals and Totalizers Amount display digits right of the decimal point, 0-4
.08
Totals and Totalizers Volume display digits right of the decimal point, 0-4
F15 - Dispenser Annunciator Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Beep annunciator on any button push
1 = Yes
2 = No
.01
Beep annunciator on physical nozzle lift
1 = Yes
2 = No
.02
Repeat annunciator beep if physical nozzle out and Push-to-start (or grade select) NOT satisfied
1 = Yes
2 = No
.03
Beep annunciator once for each eights, blanks, and zeros
1 = Yes
2 = No
F16 - WIP Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Measurement mode
1 = Liters
2 = Gallons
3 = Imperial Gallons
.01
WIP reverse pulse hysteresis, 1-64
.02
Reverse pulse Limit (after hysteresis) on an "in use" WIP, 1-99
.03
Reverse pulse Limit (after hysteresis) on an idle/unused WIP 1-255
F17 - Dispenser Limits Configuration
Sub-function numbers are in the format .0X where X = the selected configuration parameters defined as follows:
.00
Maximum number of pulse errors on an "in use" WIP (in a transaction), 1-99
.01
Maximum number of pulse errors on an idle/unused WIP, 1-99
.02
Maximum number of display errors/filling, 0-99, where 0 = disabled
.03
Stop for "no flow" or "flow lost" time limit (0 - 1000 seconds)
.04
Maximum number of consecutive no flow events w/out error, 0-10, 0 = disabled
.05
Maximum number of flow lost events w/out error, 0-10, 0 = disabled
.06
Maximum number of unfinished fillings, 0-10, 0 = Feature disabled
.07
Maximum filling amount/filling, 1-6 digits
June 2001
47

Part No. 920525 Rev A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents