Part No. 920525 Rev A - Wayne 3/VISTA series Service Manual

Blending and non-blending dispensers
Table of Contents

Advertisement

S22 - Side B Error/Event Log
Sub-statistic numbers in the format '.XX' with the range 01-50 representing the set of error/events records maintained
by the program, with the record in sub-statistic 01 being the most recent View statistic data on the two (2) data 'pages'
shown in an alternating sequence at a frequency of 1 second per page.
Note:
See
Appendix A, "Error Codes"
for a list of error codes.
Page 1 has the following format:
.HH.MM
CC.DD.NN
where:
HH = hour
MM = minute
CC = error code
DD = device number
NN = logical nozzle number
Page 1 has the event time on the Money display in the format HH.MM. The volume display data is in the format
CC.DD.NN where CC = the error/event code in the range 1-99, DD = the device number associated with the error/
event and NN = the logical nozzle 0-8 selected at detection of the event (0 = none selected).
Page 2 has the following format:
MM.DD.YY
C
where:
MM = month
DD = day
YY = year
C = filling count
Page 2 shows the event date on the Money display in the format MM.DD.YY and the filling count for the side on the
volume display.
S23 - Side A Transaction History Log
Sub-statistic numbers in the format '.XX' with the range 01-10 representing the set of transaction records maintained
by the program. The record displayed in sub-statistic 01 is the most recent and 10 is the oldest. View statistic data on
the two (2) data 'pages' shown in an alternating sequence at a frequency of 1 second per page. Page 1 has the
transaction amount on the money display. The volume display has the transaction volume. Page 2 shows the unit
price on the money display and volume display has the transaction volume.
S24 - Side B Transaction History Log
Sub-statistic numbers in the format '.XX' with the range 01-10 representing the set of transaction records maintained
by the program. The record displayed in sub-statistic 01 is the most recent and 10 is the oldest. Display of statistic
data is accomplished by the use of two (2) data 'pages' shown in an alternating sequence at a frequency of 1 second
per page. Page 1 has the transaction amount on the money display. The volume display has the transaction volume.
Page 2 shows the unit price on the money display and volume display has the transaction volume.
59
June 2001

Part No. 920525 Rev A