S21 - Side A Error/Event Log
Sub-statistic numbers in the format '.XX' with the range 01-50 representing the set of error/events records maintained
by the program, with the record in sub-statistic 01 being the most recent. Display error log data by using the two (2)
data pages shown in an alternating sequence at a 1 second per page.
Note:
See
Appendix A, "Error Codes"
Page 1 has the following format:
Page 1 has the following
format:
.HH.MM
CC.DD.NN
where:
HH = hour
MM = minute
CC = error code
DD = device number
NN = logical nozzle number
Page 1 has the event time on the Money display in the format HH.MM. The volume display has data in the format
CC.DD.NN where CC = the error/event code in the range 1-99, DD = the device number associated with the error/
event and NN = the logical nozzle 0-8 selected at detection of the event (0 = none selected).
Page 2 has the following format:
MM.DD.YY
C
where:
MM = month
DD = day
YY = year
C = filling count
Page 2 shows the event date on the Money display in the format MM.DD.YY and the filling count for the side on the
volume display.