Bosch D7212GV3 Program Entry Manual page 95

Table of Contents

Advertisement

D7212GV3 | Program Entry Guide | 5.0
Window
Default:
1
Selection:
1 to 8
Enter the window number you want to program.
W# Sunday
Default:
No
Selection:
Yes or No
Yes
Activate this window on Sundays.
No
Do not activate this window on
Sundays.
This prompt and the next six day-of-the-week
prompts select the days of the week the Opening and
Closing windows are active.
Exceptions:
To prevent the windows from activating on certain
days of the year, program Xept Holiday as Yes, and
enable at least one Holiday Index. When Xept
Holiday is Yes, the window executes on the days of
the week programmed unless the Holiday Index
designates the date as a holiday.
If Opening and Closing Windows are only needed on
certain days of the year, do not program the windows
to execute on any days of the week. Instead,
program Xept Holiday as No and select a Holiday
Index with the days of the year you want the window
to be active.
W# Monday
Default:
No
Selection:
Yes or No
W# Tuesday
Default:
No
Selection:
Yes or No
W# Wednesday
Default:
No
Selection:
Yes or No
W# Thursday
Default:
No
Selection:
Yes or No
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Schedules (Skeds)
W# Friday
Default:
Selection:
W# Saturday
Default:
Selection:
W# Open Early Begin
Default:
Selection:
Open Early Begin: This program item is one of three
required to create an Opening Window. To finish
programming an Opening Window, Open Window
Start and Open Window Stop must be programmed.
The time programmed in the W# Open Early Begin
field is the earliest time that the user is allowed to
open an area before the Opening Window Start time.
If Opening and Closing Reports are enabled,
disarming the area between midnight and the open
Early Begin time generates an Opening Report.
If A# Disable O/C in Window is set to Yes
and the area is disarmed between the Open
Early Begin time and the Open Window Start
time, the Opening event is sent with an Early
to Open modifier. If the Open Early Begin
time is the same as the Open Window Start
time, no Opening Event is sent.
If Disable O/C in Window is set to No and
the area is disarmed at any time, an Opening
Event is sent without an Early to Open or
Late to Open modifier.
Disarming the area between the Open Window Start
and open Window Stop times creates a local event in
the control panel event log, but does not send the
Opening Report to the central station.
Disarming the area between the Open Window Stop
time and before the next window's Open Early Begin
time (or midnight, whichever is earlier) generates an
Opening Event with a Late to Open modifier.
When configuring multiple windows to operate on the
same day, ensure that they are added to the system
in chronological order. For example, if three windows
are programmed to execute on Tuesday, Window 1
(W1) must occur before Window 2 (W2), and Window
2 must occur before Window 3 (W3).
No
Yes or No
No
Yes or No
00:00
HH:MM (hours and minutes)
00:00 to 23:59
EN | 95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents