Cross Point Parameters - Bosch D7212GV3 Program Entry Manual

Table of Contents

Advertisement

D7212GV3 | Program Entry Guide | 6.0
Perimeter Relay
Default:
No
Selection:
Yes or No
Yes
Change the function of the area-wide
fail-to-close relays to follow the
perimeter armed states of their
areas.
No
The area-wide fail-to-close relay
operates normally.
When set to Yes, the A# Fail to Close relay
becomes an area-wide perimeter armed relay. This
relay is activated when all areas assigned to the
same relay have perimeter points that are armed.
Early Armed Relay
Default:
No
Selection:
Yes or No
Yes
Change activation of Area Armed or
Perimeter Armed Relay to the
beginning of the exit delay time.
No
Maintain the activation of Area
Armed or Perimeter Armed Relay at
the end of the exit delay time.
When this prompt is set to Yes, the Area Armed or
Perimeter Armed Relay activates at the beginning of
the exit delay time.
Daylight Saving Time
Default:
Disabled
Selection:
Disabled or US Calendar
Disabled
The control panel clock is not
adjusted for daylight saving time.
US
The control panel clock is adjusted
Calendar
to the US start/end dates for daylight
saving.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
AUXPARM
6.10

Cross Point Parameters

This section discusses the requirements necessary to
program Cross Point functions.
Use the Cross Point function on non-fire
points only.
The Cross Point option reduces false alarms. Points
can be programmed so that the control panel needs
to see an Alarm condition within a programmed
period of time (called Cross Point Time) from at least
two points within a Cross Point Group (Table 34)
before Cross Point Alarm Events are generated.
These points must have P## Cross Point set to Yes
to generate this event.
There are five Cross Point Groups in the D7212GV3.
Each Cross Point Group consists of eight points and
is identified by the point numbers in them (for
example, Cross Points 1 to 8, Cross Points 9 to 16,
and so on). The maximum number of points that can
be programmed to meet the Cross Point criteria is
two. Point numbers from different Cross Point Groups
do not affect each other. Refer to Table 34 for a
complete listing of Cross Points comprising each
Cross Point Group.
When any point with P## Cross Point set to Yes
detects an alarm condition, the control panel starts a
timer as programmed in the Cross Point Time
prompt.
If a second Cross Point within the same Cross Point
Group detects an alarm condition, the control panel
creates a Cross Point Alarm Event for both points,
provided both points activate inside the Cross Point
Window. A Cross Point is considered to be in alarm
when it meets the criteria for Instant Alarm response.
The Cross Point index must have P## Point
Response set to a value that generates an instant
alarm response.
If a single Cross Point detects an alarm and stays
faulted throughout the duration of the Cross Point
Window, a standard Alarm Report is generated for
that point.
Conversely, if a single Cross Point detects an alarm,
then restores, and no other conditions occur, an
Unverified Event is generated for that point. A second
alarm on the first point does not create an Alarm
Event but rather an Unverified Event.
EN | 126