Release Notes for Version 7.07
Trademarks
®
Molex
is a registered trademark of Molex Incorporated.
1.0
Requirements
Table 1: Required Handlers
D5200 Handler
Version
GV2MAIN
1.03
RADXUSR1
1.06
RADXPNTS
1.08
RADXSKED
1.04
GV2AUX
1.03
9000MAIN
NA
RADXAUX1
NA
During the development of the GV2 Series
Control Panels, some D5200 Handler
version numbers were skipped. The
following version numbers were not
released.
GV2MAIN v1.01
RADXUSR1 v1.05
RADXPNTS v1.07
RADXSKED v1.03
GV2AUX v1.01
Table 2: Supporting Literature for D7212GV2
with Version 7.07 Firmware and Later
Document Name
D7212GV2 Program Entry Guide
D7212GV2 Program Record Sheet
D7212GV2 Operation and
Installation Guide
D7212GV2 Approved Applications
Compliance Guide
*
Older revisions have alphabetic revision identifiers (for
example, F01U003804B) and do not provide information
that supports version 7.05 and later firmware.
Changes
New handler for the GV2 Series Control Panels, version 7.07 and later
Updated to support GV2 Series Control Panels
Updated to support GV2 Series Control Panels, version 7.05 and later
Updated to support GV2 Series Control Panels
New handler for the GV2 Series Control Panels, version 7.07 and later
Not compatible with the GV2 Series Control Panels
Not compatible with the GV2 Series Control Panels
Part Number*
F01U003804-03
F01U003803-03
F01U003805-02
F01U003806-02
Use Remote Programming Software
(RPS) version 5.7 and later with this
software version.
To acquire an update for your D5200
Programmer, call the Bosch Security
Systems, Inc. Handler Update System,
toll-free, at (800) 657-4584. Make a
separate phone call for each handler.
Use an analog telephone line with the
D5200. The D5200 dials only pulses.
Refer to Section 10 Updating Handlers in
the D5200 Programming Manual
(P/N: 74-06176-000-B) for details on
updating handlers.
Refer to Table 3 for the required ROM kit part
number.
Table 3: ROM Kit Part Number
Control Panel Model
D7212GV2
D7212GV2
December 2007
Part Number
R20-7212V2-ROM

Advertisement

loading

Summary of Contents for Bosch D7212GV2

  • Page 1: Control Panel

    Use an analog telephone line with the GV2AUX v1.01 D5200. The D5200 dials only pulses. Refer to Section 10 Updating Handlers in Table 2: Supporting Literature for D7212GV2 the D5200 Programming Manual with Version 7.07 Firmware and Later (P/N: 74-06176-000-B) for details on updating handlers.
  • Page 2 BIS Security Engine v2.1.1271 or The following corrections and changes were made in later. This addresses the issues described in the the D7212GV2 Control Panel since Firmware 7.06: BIS SEE and GV2/G Series Technical Service Note (P/N: F01U073249).
  • Page 3 The relay deactivates when the first area disarms. • The sensitivity of the Ground Fault feature is modified to be equivalent with Version 6.90 and to prevent false reports. D7212GV2 Release Notes for Version 7.07 © 2007 Bosch Security Systems, Inc. Page 3 F01U009079-04...
  • Page 4 “Reset Panel” limits required by UL. checkbox is set, the control panel now logs a Remote Reset event instead of a Reboot Event. D7212GV2 Release Notes for Version 7.07 F01U009079-04 Page 4 © 2007 Bosch Security Systems, Inc.
  • Page 5 Parameter Checksum Failures. detection feature is solely enabled by closing • Switch S4 on the D7212GV2 Control Panel. The Service Walk Test on the D7212GV2 now shows the correct maximum number of points in • Changes now suppress the ALARM SILENCED the system.
  • Page 6: New Features

    The D7212GV2 Control Panels, version 7.05 and When RPS v5.7 or later, or GV2AUX above, support the new D1255RB and D1256 v1.03 or later, sends data to a D7212GV2 Keypads and the new D1257RB Annunciator. These control panel running v7.06 or earlier, use...
  • Page 7 This feature is always on and cannot be disabled. D7212GV2 Release Notes for Version 7.07 © 2007 Bosch Security Systems, Inc. Page 7 F01U009079-04...
  • Page 8 At any other time, the [Enter] key is required for acceptance of the code. D7212GV2 Release Notes for Version 7.07 F01U009079-04 Page 8 © 2007 Bosch Security Systems, Inc.
  • Page 9 CANCEL RPT SENT on the keypad. The burglary alarm cancel window duration is the time A# Alarm Bell programmed in the prompt. D7212GV2 Release Notes for Version 7.07 © 2007 Bosch Security Systems, Inc. Page 9 F01U009079-04...
  • Page 10: Upgrading To A Gv2 Series Control Panel

    S1 reset security. switch. This connector provides an easy way to Easy Exit Control: The D7212GV2 changes from connect an SDI device to the SDI bus without one armed state to another armed state without disconnecting the wires on SDI Terminals 29 disarming.
  • Page 11: Known Issues

    Forced Close Reports for the non-local point. • With a v7.05 or v7.06 D7212GV2 control panel, A point is local if it is configured as: starting and stopping a Fire Walk test command...