D7212GV3 | Program Entry Guide | 2.0
CC# Exit Tone
Default:
Yes
Selection:
Yes or No
Yes
This keypad sounds entry tones.
No
This keypad does not sound entry
tones.
Determines whether keypads at this address setting
emit the exit delay tone during the delay arming of an
area(s). Any keypad with a scope to arm this area
can initiate the exit tone sequence.
This prompt allows you to manage the tone by
keypad. Exit Tone can also be turned off when
programming A# Exit Tone in Area Parameters.
Assign two CCs to the same area so one
keypad emits the tone and another does
not.
CC# Arm Now Warning
Default:
No
Selection:
Yes or No
Yes
This keypad activates a tone and
displays PLEASE CLOSE NOW.
No
This keypad does not activate the
tone or display PLEASE CLOSE
NOW.
Determines whether this keypad sounds a tone and
displays the PLEASE CLOSE NOW warning on the
keypad when a Closing Window activates, indicating
the area automatically arms soon.
CC# Close Door
Default:
No
Selection:
Yes or No
This feature is not available with the D7212GV3.
Keep the default setting.
CC# Enhanced Command Center
Default:
No
Selection:
Yes or No
Yes
This keypad is a D1260 Series
Keypad.
No
This keypad is not a D1260 Series
Keypad.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Panel and Area Wide Parameters
When a D1260 Series Keypad is installed at this
keypad address, this item must be set to Yes.
Reboot the system to enable a D1260
Series keypad.
To reboot the system, close and open the
reset switch, labeled "S1 RESET,"
located in the upper right corner of the
control panel.
CC# Passcode Follows Scope
Default:
Selection:
Yes
No
Use this program to determine if this keypad follows
CC# Scope or if it only arms or disarms the area to
which it is assigned. The user must have authority
enabled in L## Passcode Arm and L## Passcode
Disarm. This feature does not affect the Function List
arming and disarming commands.
Tokens and cards disarm according to
this prompt. If this prompt is No, tokens
disarm only the Area to which the CC# is
assigned. The user must have disarming
rights for tokens and cards programmed
at the Disarm Level,. The user does not
need disarming and arming authority for
the keypad.
Yes
Yes or No
Master Arming allows a user to
change the armed state of the areas
within the scope of this keypad. If the
areas in the scope are already at the
intended armed state, they remain in
that state.
If the area to which this keypad is
assigned is armed, entering a
valid passcode disarms this area
and all other areas assigned to
the scope of this keypad.
If the area to which this keypad is
assigned is disarmed, entering a
valid passcode arms this area
and all other areas assigned to
the scope of this keypad.
Restricts the scope of the keypad to
the Area programmed in CC# Area
Assign for the purpose of executing
L## Passcode Arm and
L## Passcode Disarm only.
EN | 49