D7212GV3 | Program Entry Guide | 2.0
A# Fail to Close
Default:
No
Selection:
Yes or No
Yes
Fail to Close Report is sent for this
area if the area was not armed when
the Closing Window stop time
occurred.
Note:
Program an exit delay time in
Exit Dly Time.
No
Fail to Close Report is not sent for
this area.
If Auto Close is programmed
Yes, a Fail to Close Report is
sent because it occurs when the
Closing Window stop time
occurred.
If Disable O/C in Window is
Yes, the Fail to Close Report is
followed by Closing Late or
F(orce) Close Late.
Determines if a Fail to Close Report is sent for this
area. Use to determine if a user failed to arm the area
before the Closing Window expires. Normal Opening
and Closing Reports do not need to be programmed
to use this feature.
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Panel and Area Wide Parameters
A# Restrictd O/C
Default:
Selection:
Yes
Restrict Opening and Closing Reports for
this area. A# Area O/C must be
programmed Yes to generate Restricted
Opening and Closing Reports.
Note:
Opening/Closing Window does not affect
this report. Windows do not prevent
sending Restricted Opening and Closing
Reports from being sent. Early or late
designations are not added to Opening
or Closing Reports when they are sent
according to the rules for Restricted
Opening or Closing Reports.
No
Do not Restrict Opening and Closing
Reports for this area.
Regardless of programming in Authority
Levels L## Restricted O/C, reports are
not restricted in this area when this item
is programmed as No.
Note:
This item determines if this area can restrict Opening
and Closing Report activity.
A Restricted Opening Report refers to the control
panel sending an Area Opening Report only when
the area is disarmed after a non-fire alarm.
A Restricted Closing Report refers to the control
panel sending a Force Closed Report only when the
area was master armed with Controlled points that
were faulted during the arming sequence. The
sequence of reports generated by a restricted closing
is: Was Force Armed, Forced Point, and Forced
Close.
No
Yes or No
If a passcode is not required for
arming or disarming and this item is
Yes, the area sends only Restricted
Opening and Closing Reports. In this
case, Restricted Reports are sent
without User ID.
Was Force Armed and Forced Close
Events can still be sent to the central
station if enabled in Routing when
force arming the system.
EN | 40