NOTE: ELITEpro XC loggers equipped with a WiFi module all contain an internal antenna. An external
antenna is optional. You may toggle between the internal and external antenna (if it is available on your
logger) by selecting the appropriate radio button.
4) Select the Access Point Mode radio button in the WiFi Mode section of the dialog box.
5) Click Set Logger's Web Server Password. The Set
Logger's Web Server Password dialog box displays.
Enter a password (if desired) for use when connecting
to the loggers internal web server and click OK. The
factory default password is 1234. (NOTE: This
password is only used when connecting through a web
browser. See below.)
6) Click Save Changes in the Logger WiFi Setup dialog box.
ELOG updates the WiFi settings and prompts you to click OK in order to reset the ELITEpro XC.
NOTE: After the blue COMM LED on the ELITEpro XC device stops blinking, use the ELOG command
Logger > Communication > About the Connected Logger to verify that all entries in the Logger
Properties dialog box match the values you entered.
When using Access Point Mode the SSID will be XC + the logger serial number, the IP address will be
192.168.1.1, and the Port number will be 80.
7) Open the Wireless Network Connection dialog on your PC. (You may need to click Refresh.) Look for
an access point with the SSID (P + logger serial number) and then click Connect. Ensure that
Windows connects to the access point.