DENT Instruments ELITEpro XC Quick Start Manual

Hide thumbs Also See for ELITEpro XC:

Advertisement

Quick Links

Quick Start Guide
ELITEpro XC™
ELOG™ Software
NEED HELP?
CALL TECH SUPPORT: 541.388.4774 or 800.388.0770
IMPORTANT: Do not connect the ELITEpro XC to your
computer until you have installed ELOG 14.
E-MAIL:
DENT Instruments | 925 SW Emkay Dr. | Bend, Oregon 97702 USA
Phone 541.388.4774 | Fax 541.385.9333 |
and
TECHHELP@DENTINSTRUMENTS.COM
www.DENTInstruments.com

Advertisement

Table of Contents
loading

Summary of Contents for DENT Instruments ELITEpro XC

  • Page 1 CALL TECH SUPPORT: 541.388.4774 or 800.388.0770 IMPORTANT: Do not connect the ELITEpro XC to your computer until you have installed ELOG 14. E-MAIL: TECHHELP@DENTINSTRUMENTS.COM DENT Instruments | 925 SW Emkay Dr. | Bend, Oregon 97702 USA Phone 541.388.4774 | Fax 541.385.9333 | www.DENTInstruments.com...
  • Page 2: Elite Pro Xc™ Safety Summary And Specifications

    600V. Exceeding this voltage will cause damage to the logger and danger to the user. Always use a Potential Transformer (PT) for loads in excess of 600V. The ELITEpro XC is a 600 Volt Over Voltage Category III device.
  • Page 3: Sensor Limitations

    Battery Life: The lithium battery is only used to maintain the date and clock settings during power failure and has a life expectancy of greater than 10 years. Contact DENT Instruments for service. No accessories are approved for use with the ELITEpro XC other than those specified in the DENT Instruments product literature and price sheets.
  • Page 4: Elite Pro Xc™ Résumé De Sécurité Et Spécifications

    Le ELITEpro XC est un appareil de surtension de catégorie III. Utiliser des gants en caoutchouc approuvé avec protection mécanique et des lunettes lors de l'utilisation de l'appareil. ATTENTION: Ce LOGGER peut contenir de hautes tensions qui peuvent être dangereuses. UN PERSONNEL QUALIFIÉ...
  • Page 5 Il n'y a aucun entretien requis avec le ELITEpro XC. Respectez les points suivants: Nettoyage: Aucun agents de nettoyage, y compris l'eau, doit être utilisé sur le ELITEpro XC. Espérance de Vie de la Batterie: La pile au lithium est utilisée uniquement pour maintenir les paramètres de date et d'heure en cas de coupure de le courant et a une espérance de vie de plus...
  • Page 6: Elite Pro Xc™ Technical Specifications

    ELITE XC™ TECHNICAL SPECIFICATIONS Specification Description Single Phase-Two Wire, Single Phase-Three Wire, Three Phase-Four Wire Service Types (WYE), Three Phase-Three Wire (DELTA), DC Systems (solar, battery) Voltage Channels 3 channels, CAT III, 0-600 VAC (line-to-line) or 600 VDC Current Channels 4 channels, .67 VAC max, +/- 1 VDC max;...
  • Page 7 Specification Description Tri-colors (red, green, and blue): 1 LED to indicate communication, 4 LEDs for correct phasing (green when voltage and current on the same LED Indicators phase; red when incorrectly wired, blue for wireless, Bluetooth wireless technology, and Ethernet). Communication USB (Standard) USB standard (Type B).
  • Page 8 Minimum System Requirements Operating System Windows® 7 (32 or 64 bit),Windows 8, Vista (32 or 64 bit) or XP Processor Pentium Class 1 GHz or more recommended Hard Drive 50 MB minimum available Communications One USB Port CD Drive CD or DVD drive required for software installation...
  • Page 9: Install The Elog 14 Software And The Usb Driver

    QUICK START GUIDE The Quick Start Guide quickly gets you set up and operating with the new ELITEpro XC ™ and ELOG 14 software and is recommended for those that have experience with DENT Instruments or are familiar with power measuring products and procedures.
  • Page 10 CT-HSC-020-X (20A Mini), CT-HSC-050-X (50A Mini), CT-HMC-0100-X (100A Midi), and the CT-HMC- 0200-X (200A Midi). The use of any other CT will invalidate the UL Listing of the ELITEpro XC. Make your voltage connections (L1, L2, and N). In this scenario, L3 is not used and may be set aside.
  • Page 11: Communicate With The Elitepro Xc

    Shield Wires from DENT RoCoil CTs connected to ELITEpro XC Connect the L1, L2, and N voltage leads to the ELITEpro XC. Sometimes when connecting the L1 and L2 leads a small spark may be noted. This is normal and will not damage the meter.
  • Page 12: Create A Setup Table

    Create a Setup Table In this step you will create a Setup Table that will tell the ELITEpro XC what to measure, how often, etc. Select File > New > Setup Table File and click OK. When your computer is connected to an ELITEpro XC, the ELOG software assumes the new setup file is for the connected device.
  • Page 13: View And Retrieve Logger Data

    After connecting to the logger, click on one of the SEND SETUP TABLE to Logger command buttons on the Setup Table screen. Separate buttons are available at the top and lower left of the Setup Table screen. Sending a new Setup Table to the logger deletes any data still stored in the logger.
  • Page 14 Wall Power: Power can also be supplied using an optional wall transformer. This may be necessary when taking current-only measurements. For more information on powering the ELITEpro XC, please consult the ELITEpro XC manual which can also be found under the “Help” menu in ELOG or on the DENT Instruments website.
  • Page 15: Elog Quick Setup

    ELOG QUICK SETUP The following diagram shows how to connect the ELITEpro XC CT and voltage leads and configure ELOG’s Setup Table for the single phase, 2-wire power measurement session. Single Phase, 2-Wire As an example, configure the Setup Table as follows:...
  • Page 16: Dent Instruments Warranty Statement

    DENT INSTRUMENTS WARRANTY STATEMENT Seller warrants to Buyer that the products or services are free from substantial defect in material and workmanship under normal use given prior installation and maintenance for the period of 12 months after delivery. (SMARTloggers™ are warranted for a period of 36 months after delivery.
  • Page 17: Limitation Of Remedies

    Any amendment hereto must be written and signed by Seller. Service and Support for DENT Instruments Products Before calling, remember that many questions are answered in the Operator's Guide for your product. Furthermore, there is extensive product information on the website. In the event that you have a problem with your DENT product that you cannot resolve, please note the following information.

Table of Contents