Esc+I@ Internal Buffer Initialization - SATO S84EX Programming Reference Manual

Hide thumbs Also See for S84EX:
Table of Contents

Advertisement

15.14 Intelligent Command
15.14

ESC+I@ Internal Buffer Initialization

Internal Buffer Initialization
Hexadecimal
ESC
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within item
command
Valid range between item
[Function]
Initialize the internal buffer.
[Format]
<I@>(aa)
●Parameter
a[Internal buffer number to be initialized]
[Coding Example 1] Initialize the internal buffer number 6
<A>
<I@>06
<Z>
[Coding Example 2] Initialize all the internal buffer
<A>
<I@>
<Z>
[Notes]
1. Do not specify this command in the same item as data receive command <IR> and data send command <IT>.
2. It is not possible to undo the internal buffer data that are initialized.
3. The digit of appropriate buffer number become 0, and item name and the data contents string are deleted after the
initialization.
I@
Parameter
<49>
<40>
(aa)
16
16
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
=
Valid range :
All the internal buffer will be initialized when the buffer number is omitted.
287
ESC+I@
1 ~ 16(omissible)
Internal buffer
No
Item name Number
of digits
01
DATA1
02
DATA2
03
DATA3
04
05
06
QTY
07
08
09
10
11
12
13
14
15
16
Data contents
2
49
6
123456
4
1234
0
0
4
0010
0
0
0
0
0
0
0
0
0
0

Hide quick links: