79.1 2D code
79.1

ESC+2D32 Micro QR Code

Micro QR Code
Hexadecimal
ESC
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within item
command
Valid range between item
[Function]
Specify Micro QR code.
[Format](setting part)
<2D32>,a,bb,c
●Parameter
a [Error correction level(error correction)]
b [Size of a side]
* Recommend to specify more than 2 dots for 12dots/mm, and 4 dots for 24 dots/mm for scanner readability.
c [Data setting mode]
[Format](data part)
Manual setting (Data setting mode)
<DS>k,n~n
<DN>mmmm,n~n
Auto setting (Data setting mode)
<DN>mmmm,n~n
[Format](version specification)
<QV>pp
●Parameter
k[Input mode]
=
* Note that there is a binary specification other than above, however, the data specification command is different.
m [Number of data]
=
* Specify this setting only when the auto setting is specified in the data setting mode.
n[Print data]
=
pp
[Version]
=
* Use this setting when fix the QR symbol size. When this is not specified, it will be auto.
It will be auto when 00 is specified. The parameter error will not occur in the range of 00~40.
* Refer to the "QR code version specification command" for more details.
[Note 1]
1. When Kanji is specified in the <DN>, specify the size of number of Kanji character x2.
2. When auto setting is on and <DN> specification, 80H~9FH and E0H~FFH is treated as Kanji mode and binary cannot be
specified.
[Coding Example 1]
Error correction level: 7%, size of a side: 04
<A>
<V>100<H>200
<2D32>,L,04,0
<DS>1,012345
<Q>2
<Z>
[Note 2]
1. The code will not be printed when a parameter other than above is specified or number of print data does not match.
2. The data specification command in the data part varies according to the setting of the parameter part or specified data
contents.
2D32
<32>
44>
<33>
<32>
<
16
16
16
16
=
L
M
Q
=
Valid range
=
0
1
* This is used when the input mode is numeric mode, alphanumeric mode and Kanji code.
* This is used when specified by binary.
* The input mode is automatically switched by the input data.
* This is used when specifying the version.
1
:
Numeric mode
2
:
Alphanumeric mode
3
:
Kanji mode(Shift JIS Kanji code)
Valid range
: 1~15
data
00~40(MODEL2)
ESC+2D32
Parameter
,a,bb,c
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
:
7%
:
15%
:
25%
:
01~99(dots)
:
Manual setting
:
Auto setting