ID50/60
operating
manual
997-264-000-8, Issue 8 January 2007

Advertisement

Table of Contents
loading

Summary of Contents for Notifier ID50 SERIES

  • Page 1 ID50/60 operating manual 997-264-000-8, Issue 8 January 2007...
  • Page 2: Table Of Contents

    ID50 Series Panel - Operating Manual Contents Introduction Associated Documents The ID50 / ID60 Series Panel 1.2.1 Device Type Abbreviations Cleaning Panel Controls and Indicators Controls Indicators Automatic Alarms - What to do Fire 3.1.1 Fire in Delayed Mode Pre-alarm Fault 3.2.1 Power Fail...
  • Page 3 ID50 Series Panel - Operating Manual 4.9.6 Buzzer - User Option 4.9.7 Keyboard - User Option 4.10 DISABLE / ENABLE - User Option 4.10.1 Zones - User Option 4.10.2 Outputs - User Option 4.10.3 Day Mode - User Option 4.10.4 Delays - User Option 4.11 CLOCK - User Option...
  • Page 4 ID50 Series Panel - Operating Manual ID50 Series Panel 997-264-000-8, Issue 8 January 2007...
  • Page 5: Introduction

    Commissioning Configuration Manual (Ref. 997-263-000-X). 1.2 The ID50/ ID60 Series Panel The panel, as supplied by NOTIFIER, is a 1-loop, 16-zone Analogue Addressable Panel. The single loop has the capacity for up to 99 analogue sensors plus up to 99...
  • Page 6: Device Type Abbreviations

    ID50 Series Panel - Operating Manual 1.2.1 Device Type Abbreviations Throughout this manual the panel may refer to devices by an abbreviated name. The following table lists the device type abbreviation and its description. Abbreviation Type Description Plant Warning Input AVR* Advanced VIEW™...
  • Page 7: Panel Controls And Indicators

    ID50 Series Panel - Operating Manual Panel Controls and Indicators The panel’s controls and indicators are used to operate the overall system and display the panel status. The panel has five function pushbuttons, twelve numeric/cursor keys and thirty-two zonal LED indicators, two ‘FIRE’ indicators and fourteen system status LED indicators.
  • Page 8: Indicators

    ID50 Series Panel - Operating Manual 2.2 Indicators The panel status indicators comprise three groups: a. Zone Status LED indicators. b. Panel/System LED indicators. c. Visible/Audible indicators. Zone Status LED Indicators • ZONE FIRE - these LEDs indicate affected zone(s).
  • Page 9: Automatic Alarms - What To Do

    ID50 Series Panel - Operating Manual Automatic Alarms - What to do Before any automatic alarms have been sounded the panel only operates in display mode (quiescent state). The user must then turn the keyswitch to the right or enter a Level 2 access code to enable the panel’s pushbuttons.
  • Page 10 ID50 Series Panel - Operating Manual Recommended operator actions: Note: In the recommended operator actions described below EN54-2: 7.6.1, 7.8, 8.7.1, only MUTE BUZZER and END DELAY are selectable 9.1.2 at Access Level 1. The operation of EXTEND DELAY, Ensure EN54 compliance EVACUATE, SILENCE, RESOUND and RESET must for access to controls.
  • Page 11: Fire In Delayed Mode

    ID50 Series Panel - Operating Manual 3.1.1 Fire in Delayed Mode The DeIayed Mode introduces a delay between an alarm being detected and the sounders and output modules activating. Depending upon the panel configuration, this may be a single delay or a 2-stage delay (an initial brief delay which may be extended by pressing EXTEND DELAY to allow an investigation).
  • Page 12: Pre-Alarm

    ID50 Series Panel - Operating Manual 3.2 Pre-alarm When one or more input devices signal to the panel a reading higher than normal but not yet at the FIRE level, this is a PRE-ALARM condition. Automatic panel actions a. Intermittent operation of the internal buzzer (one second ON, one second OFF).
  • Page 13: Fault

    ID50 Series Panel - Operating Manual 3.3 Fault Automatic panel actions: If a fault occurs, the panel automatically does the following: a. Operates the internal buzzer (2 sec. on, 1 sec. off). b. Flashes the appropriate FAULT LEDs, including numbered ZONE FAULT/ DISABLE / TEST LED(s) if appropriate.
  • Page 14: Power Fail

    ID50 Series Panel - Operating Manual 2 If a service contact number has been entered during panel commissioning, the LCD alternates between the fault message(s) and the following: FAULT 01 / 03 14:55 For Service Contact ***** ****** Note: Press the MUTE BUZZER pushbutton to silence the panel’s internal buzzer.
  • Page 15: Plant Alarm

    ID50 Series Panel - Operating Manual 3.4 Plant Alarm A Plant Alarm indication is the default configuration setting for ID50 Series fire control panels. In this configuration, the panel operates as follows: A Plant Alarm message is displayed if the panel detects a non-fire input (AUX) configured in zones 17 to 32.
  • Page 16: Operator Actions At Panel

    ID50 Series Panel - Operating Manual Operator Actions at Panel 4.1 Introduction Operator actions at the panel require the correct pushbutton and access code entry. The LCD and the user pushbuttons located on the panel allow the following actions to be carried out: a.
  • Page 17: Internal Buzzer

    ID50 Series Panel - Operating Manual 4.1.2 Internal Buzzer The panel has an internal buzzer which gives a local warning when any of the following is detected: a. Fire condition. b. Pre-alarm condition. c. Fault condition. 4.1.3 Access Codes With the exception of the Loop Booster Output Test option,...
  • Page 18: Keyswitch

    ID50 Series Panel - Operating Manual 4.1.4 Keyswitch The panel is fitted with a keyswitch which provides an alternative to the Level 2 access code. If the keyswitch is in the enabled position, it overrides the requirement for a Level 2 access code. Therefore, if an alarm condition occurs the keyswitch enables the immediate operation of the control keys.
  • Page 19: End Delays/Evacuate Pushbutton

    ID50 Series Panel - Operating Manual 4.4 END DELAY / EVACUATE Pushbutton The END DELAY/EVACUATE pushbutton is used to initiate the Evacuate procedure. If this pushbutton is operated while a delay is active, all delays are cancelled and all sounders designated in the pre-configured Evacuate rule are activated.
  • Page 20: Silence/Resound Pushbutton

    ID50 Series Panel - Operating Manual 4.5 SILENCE / RESOUND Pushbutton The term ‘silence’ as used throughout this manual, describes a temporary state the panel enters whenever the SILENCE / RESOUND pushbutton is pressed to stop the sounders operating. While the panel is in this state, a...
  • Page 21: Reset Pushbutton

    ID50 Series Panel - Operating Manual 4.6 RESET Pushbutton The RESET pushbutton is used to clear all non-quiescent conditions and return the panel to a normal quiescent condition. Provided that the control keys have been enabled for Level 1 operation, the following occurs: a.
  • Page 22: Numeric Keys

    ID50 Series Panel - Operating Manual 4.7 Numeric Keys When using any numeric key, each operation is confirmed by a sharp audible bleep. At Access Level 1, the numeric buttons have NO function until an alarm condition occurs. The alarm condition enables the ‘...
  • Page 23: Level 2 Option Menus

    ID50 Series Panel - Operating Manual 4.8 Level 2 Option Menus The following Level 2 Option Menus are available after a correct Level 2 access code has been input or the keyswitch has been operated. The menu map at left shows an overview of the Level 2 menus.
  • Page 24: Test - User Option

    ID50 Series Panel - Operating Manual 4.9 TEST - User Option The following tests are available at Access Level 2 from the Test - User Option menu: a. LEDs. b. LCD. c. Zones. d. Auto High Test. e. Outputs. f. Buzzer.
  • Page 25: Leds - User Option

    ID50 Series Panel - Operating Manual 4.9.1 LEDs - User Option This option, selected from the Test menu, illuminates each LED in turn. To test the panel LEDs, enter access Level 2 and follow the procedure below: 1 Using the numeric keypad, press ‘...
  • Page 26: Zones - User Option

    ID50 Series Panel - Operating Manual 4.9.3 Zones - User Option The Test Zones option, selected from the Test Menu, allows the user to perform a walk test on one zone at a time. During the walk test the TEST and relevant ZONE FAULT/DISABLE/TEST LEDs are illuminated, indicating that the system and zone is in TEST mode.
  • Page 27 ID50 Series Panel - Operating Manual 3 To end the walk test: a. For a specified zone: at the Test Zones menu, press the ‘ ’ button on the numeric keypad to select the View/Stop Test menu: [STOP WALK TEST] Select Zone: 01...
  • Page 28: Auto High Test - User Option

    ID50 Series Panel - Operating Manual After a few seconds, the panel will automatically return to Test Mode and the device LED will be turned off. The panel is then ready to test the next device. Note: Up to one minute must be allowed for smoke sensors to clear.
  • Page 29: Outputs - User Option

    ID50 Series Panel - Operating Manual 4.9.5 Outputs - User Option The Test Outputs option, accessed from the Test Menu, tests the panel’s internal sounder and relay circuits and the Signalling Line Circuit (SLC) loop outputs. To perform this test:...
  • Page 30: January

    ID50 Series Panel - Operating Manual Test Loop Booster Outputs A number of tests are available to satisfactorily test the To perform a Loop Booster operation of the Loop Booster Modules (LBMs) during output test an access level 3 alarm conditions. The tests are designed so that the power delivered to the loop by the panel can be switched off from passcode ( is required.
  • Page 31: Buzzer - User Option

    ID50 Series Panel - Operating Manual 4.9.6 Buzzer - User Option The Buzzer User Option, selected from the Test Menu, tests the internal buzzer. Proceed as follows: [U0] 1 : Test 2 : Disable/Enable 3 : Clock 4 : View Mode 5 : Commission 1 Using the numeric keypad, press ’...
  • Page 32: Disable / Enable - User Option

    ID50 Series Panel - Operating Manual 4.10 DISABLE / ENABLE - User Option This option allows the user to disable or enable (depending on their current state) the following parts of the system: a. Zone (Device or Full Zone). b. Outputs.
  • Page 33 ID50 Series Panel - Operating Manual 3 The LCD then displays the current state of the zone (Fully enabled, Fully disabled or Part disabled) and prompts for selection of Full Zone or Devices in zone: Note: Press the ‘ ’ buttons to step to the previous/ next zone and confirm using the ‘...
  • Page 34 ID50 Series Panel - Operating Manual Repeat until all devices are in the required state (either disabled or enabled). The DISABLEMENT LED remains illuminated if one or more devices are disabled. It is extinguished when all devices have been enabled.
  • Page 35: Outputs - User Option

    ID50 Series Panel - Operating Manual 4.10.2 Outputs - User Option The Outputs option allows the user to disable or enable all sounders, the extinguishant system (if fitted), and relay and control outputs. To Disable/Enable these outputs, proceed as follows:...
  • Page 36: Day Mode - User Option

    ID50 Series Panel - Operating Manual [U0 Disable/Enable] 1:Zone 2:Outputs 3:Day Mode 4:Delays The FIRE CONTROL O/P: FAULT/DISABLED, FIRE OUTPUT: FAULT/DISABLED and the SOUNDERS DISABLED LEDs extinguish when the corresponding outputs have been enabled. The DISABLEMENT LED will only extinguish when ALL disablements have been enabled.
  • Page 37: Delays - User Option

    ID50 Series Panel - Operating Manual 4.10.4 Delays - User Option The Disable / Enable Delays option allows the user to cancel or initiate the Delays function of the panel, which is configured during commissioning (refer to 997-263 ID50 Series Panel Installation, Commissioning and Configuration Manual, Sections 5.5.5.4 Primary/...
  • Page 38: Clock - User Option

    ID50 Series Panel - Operating Manual 4.11 Clock - User Option The CLOCK User Option allows the user to enter or edit the following: a. Time. b. Date. To edit the CLOCK - User Option: 1 At the ‘Status: NORMAL’ message, press the ‘...
  • Page 39: Time - User Option

    ID50 Series Panel - Operating Manual 4.11.1 Time - User Option The Time User Option allows the user to enter or edit the current time displayed on the LCD. To edit the time, proceed as follows: 1 Press the ‘...
  • Page 40: Date - User Option

    ID50 Series Panel - Operating Manual 4.11.2 Date - User Option The Date User Option allows the user to enter or edit the current date displayed on the LCD. To enter or edit the date, proceed as follows: 1 Using the numeric keypad, press the ‘...
  • Page 41: View Mode - User Option

    ID50 Series Panel - Operating Manual 4.12 View Mode - User Option The VIEW MODE User Option allows the user to view the following system parameters: a. Log b. Devices on the loop c. Faults d. Input Events e. Disablements on the loop f.
  • Page 42: Log - User Option

    ID50 Series Panel - Operating Manual 4.12.1 Log - User Option The Log User Option allows the user to view all logged events, one at a time. To display the Log, from the VIEW Mode menu: 1 On the numeric keypad, press the ‘...
  • Page 43: Devices - User Option

    ID50 Series Panel - Operating Manual 4.12.2 Devices - User Option The Devices User Option allows the user to observe all loop devices in turn. To view Devices, from the View Mode menu: [U0 View] 1:Log 2:Devices 3:Faults 4:Input Events...
  • Page 44: Faults - User Option

    ID50 Series Panel - Operating Manual 4.12.3 Faults - User Option This menu option allows the user to view active faults while the normal active fault display has been overridden by a higher priority display (alarms). To view Faults, from the View Mode menu: 1 On the numeric keypad, press the ‘...
  • Page 45: Input Events - User Option

    ID50 Series Panel - Operating Manual 4.12.4 Input Events - User Option The Input Events menu option allows the user to view active input events/plant alarms while the normal active input events/plant alarms display has been overridden by a higher priority display (alarms). To view Plant Alarms, from the VIEW Mode menu: 1 Using the numeric keypad, press the ‘...
  • Page 46: Disabled - User Option

    ID50 Series Panel - Operating Manual 4.12.5 Disabled - User Option The Disablement User Option allows the user to view all current loop-based input disablements recorded on the system. To view each disablement in turn, from the VIEW Mode menu: 1 Using the numeric keypad, press the ‘...
  • Page 47: Voltages - User Option

    ID50 Series Panel - Operating Manual 4.12.7 Voltages - User Option The Voltages User Option allows the user to view the Voltages of various parts of the system. To view these Voltages, from the View Mode menu: 1 Using the numeric keypad, press the ‘...
  • Page 48: Version - User Option

    The Commissioning menu allows the engineer to configure the system in preparation for handover. For details concerning commissioning and configuring the system, refer to 997-263, ID50 Series Panel - Installation, Commissioning & Configuration Manual, Sections 4 and 5. 4.14 Print The RS232 Protocol option has to be set to ‘Printer’...
  • Page 49: January

    ID50 Series Panel - Operating Manual 3 Select the appropriate print option from the Log menu Where no history exists using the appropriate numeric key. You are prompted for a selected print to enter the dates of the event log period you wish to option, the option will print.
  • Page 50 ID50 Series Panel - Operating Manual Appendix 1 - Log Book In accordance with EN54 part 14, it is the user’s responsibility to maintain a log book and to record all events resulting from or affecting the system. The log book should be kept in a place accessible to authorised persons (preferably near the control panel).
  • Page 51 ID50 Series Panel - Operating Manual Event Data Date Time Event Action Required Date Completed Initials 997-264-000-8, Issue 8 A1 - 2 January 2007...
  • Page 52 ID50 Series Panel - Operating Manual Event Data Date Time Event Action Required Date Completed Initials A1 - 3 997-264-000-8, Issue 8 January 2007...
  • Page 53 ID50 Series Panel - Operating Manual Event Data Date Time Event Action Required Date Completed Initials 997-264-000-8, Issue 8 A1 - 4 January 2007...
  • Page 54 ID50 Series Panel - Operating Manual Appendix 2 - Maintenance Create a log book (see Appendix 1) in accordance with the recommendations of EN54 Part 14. This log book should be used and maintained for recording events as described below.
  • Page 55 ID50 Series Panel - Operating Manual Appendix 3 ID60 Single Loop Panel Differences The ID60 Panel differs from the ID50 Panel in that it supports Very Intelligent Early Warning (VIEW ) and SMART 4 multi-criteria sensors. This appendix describes differences to the user operations required by the ID60 Panel.
  • Page 56 Charles Avenue T: +44 (0) 1444 230 300 Burgess Hill F: +44 (0) 1444 230 888 W. Sussex E: sales@notifierfiresystems.co.uk RH15 9UF www.notifierfiresystems.co.uk local distributor Quality Systems Certificate No. 154 Assessed to ISO9001 Every care has been taken in the preparation of this document but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice.