Pipe Installation - GE CyberDome Series Installation Manual

Cyberdome series
Table of Contents

Advertisement

CyberDome Series Installation Manual
A06-8SG0/B/April2006/1033921C
Step 15)
Push the cables and interface
module back into the swing arm,
guide the flange of the housing
into the collar of the swing arm
(matching up the mating holes),
and fasten the housing to the
swing arm using the three
10-32x3/8 screws provided. See
Figure 37.
Step 16)
Proceed to RS422 Termination on page 31.
After the PTZ assembly and acrylic dome are installed, which starts with the
RS422 termination on page 31, you'll want to loosen the pivot locking screws on
the mounting socket and swing the swing arm (with CyberDome attached) out to
the desired position, and again securely tighten the pivot locking screws.
Method 3: Pipe Installation
The 7-inch pendant housing contains a 1.25 in. NPT pipe flange for pipe mounting.
Adhere to the following pipe requirements:
Use only Schedule 40 pipe.
The pipe must be at least 5 in. (12.7 cm) in length to allow for wire connections.
The pipe must be reamed inside at the CyberDome end.
The pipe must be able to support a 35 lb (15.88 kg) load.
For outdoor applications, Teflon tape must be applied to the pipe to assure that no water
enters the housing.
To install the 7-inch pendant housing onto a threaded pipe, proceed with the following steps:
CAUTION!
DO NOT provide power to the housing until all installation steps are complete.
Step 1)
Securely mount the pipe from which the pendant housing will be suspended.
Remember that the pipe must be able to support a 35 lb (15.88 kg) load.
Step 2)
Feed the video, 24 VAC, and RS422 control cables through the pipe.
Step 3)
Prepare the cables as shown in Figure 38.
Figure 38: Preparing the Cables
Housing Installation
Figure 37. Connecting the Housing to the Swing
Arm
25