Housing Installation
30
Step 7)
Thread the RS422, 24VAC, and video cable through the flexible conduit, and
prepare them as shown in Figure 45. Feed the cables into the upper housing,
leaving approximately 4 in. (10.16 cm) of slack, and attach the conduit to the
housing with a locking nut.
CAUTION!
If the power and RS422 cables are reversed in step 8 (below), the CyberDome will be damaged.
Step 8)
Locate the interface module mounted in the upper housing. See Figure 46. Con-
nect the 24VAC, RS422, and video cables to the interface module as shown.
Figure 46: Heavy-Duty Housing Cable Connections
Step 9)
Proceed to RS422 Termination on page 31.