GE CyberDome Series Installation Manual page 19

Cyberdome series
Table of Contents

Advertisement

CyberDome Series Installation Manual
A06-8SG0/B/April2006/1033921C
CAUTION!
DO NOT connect the 24VAC power wires to the video or RS422 connections, or the CyberDome will
be damaged.
Step 11)
Wire the interface module (see Figure 24):
a) For power:
Connect the 24VAC wires to the 24VAC terminals on either module.
b) For data:
While observing polarity, connect the RS422 control signal twisted-pair wires
to the DATA IN terminals on either module.
c) For video:
If sending video via UTP, observe polarity and connect the video twisted-pair
wires to the VIDEO OUT terminals on the UTP module.
If sending video via coaxial, connect the BNC to the coaxial module.
Figure 24. Connections to Either CyberMount Interface Module
Step 12)
Insert the interface module into its mounting slot up in the CyberMount. See
Figure 25.
Figure 25. Fitting the Interface Module into the CyberMount
Housing Installation
19

Advertisement

Table of Contents
loading

Table of Contents