NEC Exress5800 Series User Manual page 156

Table of Contents

Advertisement

Chapter 3 Setup
4. After a while, the following message is displayed on the screen. (The on-screen message depends on
your environment.)
Press <F2> SETUP, <F3> Internal Flash Memory, <F4> ROM Utility, <F12> Network
By pressing the designated function key following messages, you can call the functions below upon
completion of POST.
<F2> key:
<F3> key:
<F4> key:
<F12> key: Boot from network.
5. When Legacy is specified for Boot Mode, if a controller which has its dedicated BIOS such as a RAID
Controller is installed, a message that prompts you to start the dedicated utility to configure the card is
displayed.
Example: If an optional RAID Controller is installed
Press <Ctrl> <R> to Run MegaRAID Configuration Utility
The utility starts by pressing <Ctrl> + <R> keys.
For details on the utility, refer to the manual supplied with each optional board.
Depending on the configuration, the message "Press Any Key" might appear to prompt a key entry. This
is a behavior of the BIOS of the optional board. Continue to operate after checking the manual of the
optional board.
6. When Secure Boot is set to Enabled in Security menu and Invalid Signature Detection is set to Halt
in BIOS Setup Utility (SETUP), the message will be displayed saying that the invalid signature data was
detected in the following cases:
・The boot image in a bootable device is unsigned
・The signature of the boot image in a bootable device is illegal
In such cases, turn off this server and check that the signature of the boot image in a bootable device is
correct. Connect the device for which Secure Boot is enabled to the server, and then turn on the server
again.
156
Run BIOS Setup Utility (SETUP). For information on the SETUP, see Chapter 3 (2. BIOS
Setup Utility (SETUP)).
Run
EXPRESSBUILDER
EXPRESSBUILDER, see Chapter 3 (4. EXPRESSBUILDER).
Note
<F3> key is acceptable only for 5 seconds after the message is displayed.
If bootable CD/DVD is inserted into optical disk drive, the system starts from
CD/DVD even if <F3> key is pressed.
Run Offline Tools. For information on Offline Tools, see Chapter 1 (9. Offline Tools) in
"Maintenance Guide".
If One time or Always is specified for Power Management Policy in Server
Tips
menu of BIOS SETUP, a message indicating power consumption is being
measured is displayed instead of the message shown above. Wait for a while until
measurement is complete.
Express5800/R120g-2E User's Guide
from
Internal
Flash
Memory.
1. Turning on the Server
For
information
on

Advertisement

Table of Contents
loading

This manual is also suitable for:

R120g-2eExp330aNec express5800 series

Table of Contents