Handling precautions

Be sure to observe the following precautions for the proper functioning of the server. Ignoring the precautions
may cause server malfunction or failure.
Do not use any cell phone or PHS and switch off them near the server. Electric waves from such
devices can cause server to malfunction.
Install the server in an appropriate place. For details about the installation location, see Chapter 2
Preparations (2. Installation and Connection).
Before connecting/removing cables to/from peripheral devices, make sure that the server is off and
unplug the power cord, if they are non plug-and-play devices.
Connect the provided power cord to a 100/200 VAC outlet.
Make sure that the access LED on the server is off before turning off the power or ejecting an optical
disk.
Wait for at least 30 seconds before connecting power cord to power outlet after disconnecting it.
If any Uninterruptible Power Supply (UPS) unit is connected, set it to wait for at least 30 seconds
before turning on the server after power off.
Do not press the POWER switch to turn on the server before the STATUS LED1, 2 (amber) is unlit.
Wait for at least 30 seconds before turning on the server after turning off the server.
Turn off the server and unplug the power cord before moving it.
Regularly clean the server to prevent various types of failure. See Chapter 1 Maintenance (2. Daily
Maintenance) in "Maintenance Guide" for details.
Momentary voltage drop may occur due to lightning strike. To prevent this, use of UPS is
recommended.
Any copy-protected CD that does not conform to standards is not supported.
In the following cases, check and adjust the system clock before operation.
− After transportation
− After storage
− After a period of disuse in which storage conditions did not conform to those at which server operations
are guaranteed (Temperature: 5°C to 40°C [5°C to 45°C when an option is installed, subject to
restrictions on the configuration], Humidity: 20% to 80%)
Check the system clock approximately once per month. Use of a time server (NTP server) is
recommended if high accuracy timing is required by the system.
Observe the storage conditions (Temperature: −10°C to 55°C, Humidity: 20% to 80%, No
condensation of moisture) to store the server.
Do not power off or reset the server, nor disconnect the power cord before POST completes.
If this server, internal optional devices, and media set for the backup devices (tape cartridges) are
moved from a cold place to a warm place in a short time, condensation will occur and cause
malfunctions and failures when these are used in such state. To protect important stored data and
property, make sure to wait for a sufficient period to use the server and components in the operating
environment.
Reference: Time effective at avoiding condensation in winter (more than 10°C differences between the
room temperature and atmospheric temperature)
Disk devices: Approximately 2 to 3 hours
For optional devices, we recommend you use our NEC products. Even if they are successfully
installed or connected, installation of unsupported devices can cause the server to malfunction or
even failure. You will be charged to repair failure or damage caused by use of such products even
within warranty period.
Express5800/R120g-2E User's Guide
Warnings and Additions to This Document
Tape media: Approximately 1 day