Identification of electrical system failures
Hide thumbs Also See for CNK 50 DRAKON:
Table of Contents

Advertisement

10 -
SIGNAL
B
10

TROUBLE SHOOTING

THE TURN INDICATORS, STOP LIGHT AND INSTRUMENT PANEL LIGHTS DO NOT COME ON;
Check
1) Fuse 10A
2) Battery
3) Main switch
4) Signal system wiring
1 Fuse 10A
• Remove the fuse
• Connect Tester ( ) to the fuse
• Check the fuse for continuity
2 Battery
• Check the battery conditions
Minimum voltage: 12,5V
Specific gravity electrolyte level:
1.280 g/dm3
Electrolyte level
05188073
IDENTIFICATION OF ELECTRICAL
SYSTEM FAILURES

SIGNAL SYSTEM

THE REV COUNTER AND HORN DO NOT WORK
CONTINUITY
CORRECT
NO CONTINUITY
Faulty fuse
INCORRECT
Recharge or replace battery
Refill with distilled water
24
03/06
DRAKON 50 NKD
Replace
Clean the terminals