F339
Heavy-Load Torque During Reverse Acceleration
Program Special Crane/Hoist Load
During reverse acceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Heavy-Load Torque During Deceleration in the Reverse
Direction
Program Special Crane/Hoist Load
During reverse deceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Frequency for Automatic High-Speed Operation at Light-
Load
Program Special Crane/Hoist Load
This parameter establishes the speed that the ASD will ramp to when operating
in the Light-Load High-Speed mode.
140
Direct Access Number — F339
Parameter Type — Numerical
Factory Default — (ASD-Dependent)
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F340
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F341
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Yes
Minimum — 30.0
Maximum — Upper Limit (F012)
Units — Hz