F330
High-Speed Operation at Light Load
Program Special Crane/Hoist Load
This parameter enables the Light-Load High-Speed function by selecting an
operating mode. The Light-Load High-Speed function accelerates the output
frequency of the ASD from the programmed speed to the setting established in
F341.
This parameter may be disabled.
If either of the other selections are made and configured,
criteria of
F331
F333
are met, the Light-Load High-Speed function is
enabled and this parameter determines the operating mode of the Light-Load
High-Speed function.
Settings:
0 — Disabled
1 — Reserved
2 — Automatic Enable - Automatic Speed (
3 — Automatic Enable - Preset Speed (Preset ID
4 — Discrete Enable - Automatic Speed (
pg. 217)
5 — Discrete Enable - Preset Speed (Preset ID
item 60 of Table 8 on pg. 217)
Light-Load High-Speed Operation Switching Lower-Limit
Frequency
Program Special Crane/Hoist Load
This parameter sets an output frequency threshold that, once surpassed, allows
the Light-load High-Speed function to be used.
The Light-Load High-Speed function may be used if the frequency threshold
(F331) and the following conditions are met:
1) Light-Load High-Speed Operation Enable is configured at F330.
2) The output torque is less than the setting established in
the frequency setting here.
Light-Load High-Speed Operation Load Wait Time
Program Special Crane/Hoist Load
After the time setting of
F333
time that the Light-Load High-Speed criteria must be met until the Light-
Load High-Speed function engages.
Light-Load High-Speed Operation Load Detection Time
Program Special Crane/Hoist Load
This parameter determines the length of time that the load requirement must
meet the Light-Load High-Speed criteria before the Light-Load High-Speed
Enable (F330) is recognized.
Once recognized, the timer setting of
Load High-Speed function.
138
F341
)
is OR'ed w/1000
Bin
F341
) (see item 60 of Table 8 on
is OR'ed w/1000
Bin
F335
times out, this parameter determines the length of
F332
must expire to engage the Light-
Direct Access Number — F330
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
and after the
)
Bin
) (see
Bin
Direct Access Number — F331
Parameter Type — Numerical
Factory Default — 40.0
Changeable During Run — Yes
Minimum — 30.0
Maximum — Upper Limit (F012)
Units — Hz
when reaching
Direct Access Number — F332
Parameter Type — Numerical
Factory Default — 1.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Direct Access Number — F333
Parameter Type — Numerical
Factory Default — 1.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds