URL
Poll Rate
Auto Config Status Shows auto config status including when the script was last run, URL
Run Script
Sample Script
The auto config script file (
VBrick parameters and force an "apply" as needed. This example shows how to set various
recorder parameters. Note that a
<XML Header>
<?VBEXECUTEFORCE?>
<VBRICK>
vbrickHDRecorderControlMode = 1
vbrickHDRecorderControlIrEnable = 1
vbrickHDRecorderControlName = event1record.mpg
vbrickHDRecorderControlDuration.value = 30
vbrickHDRecorderControlBatchEnable = 1
vbrickHDRecorderControlApplySet = 2
</VBRICK>
Note Text files created on Windows machines have different line endings than those created
on Unix or Linux machines. Windows machines use a carriage return and line feed
(
) whereas Unix machines use line feed (
\r\n
machine must be modified in order to work properly on a Unix machine.
VBrick MPEG-4 Appliance Admin Guide
Valid path to a URL script file, for example:
. Default = blank.
config.xml
The rate at which the appliance checks the config file. 0–1440 minutes
(default = 0).
connection errors, etc. Press Refresh to update.
Edit mode only. Run the script now.
) is an .xml file with the following syntax. It can set any
config.xml
task is required.
VBEXECUTE
<?VBEXECUTEIFDIF?>
or
MPEG-4 Configuration
www.myserver.com/
) only. A script created on a Windows
\n
59