AD Boivin SNOW-HAWK 800 HO 2007 Shop Manual page 19

Table of Contents

Advertisement

MPEM
1. 2-circuit housing (BL and WT/BL wires)
2. 6-circuit housing
3. 2-circuit housing (BK and WT/BL wires)
4. 12-circuit housing
MAIN CHASSIS GROUND CONNECTION
Raccourci vers Extranet.lnk
The main chassis ground of the entire electrical system is
located on the MAG side chassis rail just above the ignition coil,
as indicated at right.
WARNING
It is of utmost importance that the bolt AND locknut
securing the ground connection's ring lug to the chassis
is well tightened in in full contact with the chassis. A bad
ground connection can cause other component failures.
The main wiring harness is divided into several segments
immediately after the MPEM. The following three sections go
vertically up the steering plate and towards the steering column.
Temperature Warning Light
1. Two 1-circuit connectors (BK and BK/WT wires)
Fuse
2. Fuse and fuse housing, installed with one rivet on the
choke cable bracket.
Relay
3. Relay and connector, installed with one rivet on the
vertical steering plate.
WIRE, CABLE AND HOSE ROUTING 16-3
1
2
3
Ground
1
1
2
2
3
3
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh-man-2007

Table of Contents