19, 20, 21 Calibration Screw, Washer and Lock Nut
When installing calibration screw, make sure to install
o
washer as shown.
Torque locking nut to 10 N•m (89 lbf•in).
o
28, Pin
Always use the same type of pin as originally installed when
servicing. Different types have different weights for calibration
purpose. Refer to TECHNICAL DATA.
12, 13, 14, Screw, Dowel Tube and Ramp
Insert dowel tube from chamfered side. Make sure ramp
o
is centred on dowel tube
Position dowel tube split at the angle A.
o
PRIMARY TRANSMISSION SYSTEM 8-13
1- Washer
1- Chamfered side