LOCATION 25 - ZONES 1-8 CONFIGURATION GROUP (8 segments, numerical data)
Location 25 contains the configuration group (zone type) for zones 1-8. Segment 1 is for zone
1, and segment 8 is for zone 8. You will find the default configurations in the table above.
LOCATION 26-36 - RESERVED

General options

LOCATION 37 - SIREN AND SYSTEM SUPERVISION (7 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options.
Segment 1
Segment 2
Segment 3
Segment 4
NX-4-EUR Installation manual
1 =
On: if siren sounds for "Telephone Line Cut" when armed
2 =
On: if siren sounds for "Telephone Line Cut" when disarmed
3 =
On: if siren blast at arming (pulse)
4 =
On: if siren blast at exit expiration (pulse)
5 =
On: if siren blast at closing kiss-off (pulse)
6 =
On: if siren sounds during a "Cross Zone" verification time
7 =
On: if siren sounds for a zone or box tamper
8 =
On: if siren blasts 1 time for keyswitch or wireless arming; 2 times for
disarming
1 =
On: if siren driver should be a voltage output. Off: if on-board siren
driver is enabled
2 =
On: if sirens sound for expander trouble
3 =
On: for zones to restore immediately. Off: for zones to restore only
when the siren is off or disarmed
4 =
On: if dynamic battery test is performed at arming. Off: if dynamic
battery test is performed at disarming (See location 40)
5 =
On: if battery missing test is performed every 12 seconds
6 =
On: if manual bell test is performed during [*]-[4]-[4] test function
7 =
On: if manual communicator test is performed during [*]-[4]-[4] test
function
8 =
On: if Box Tamper terminals on the control panel are enabled
1 =
On: if box tamper report is enabled
2 =
On: if AC fail reporting is enabled
3 =
On: if low battery reporting is enabled
4 =
On: if Aux. power overcurrent report is enabled
5 =
On: if siren supervision report is enabled
6 =
On: if restore telephone line cut report is enabled
7 =
On: A+B Alarm. Off: cross-zoning
8 =
On: if expander trouble reporting is enabled
1 =
On: if fail to communicate report is enabled
2 =
On: if log full report is enabled
3 =
On: if autotest report is enabled
4 =
On: if start/end programming report is enabled
5 =
On: if end download report is enabled
6 =
On: if sensor low battery report is enabled
7 =
On: if sensor missing report is enabled
Page 49