INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED
12
2
This zone will be instant when the system is armed and no entry or exit delay is being timed.
It is delayed during entry and exit delay times. If a "Cross Zone" is not being timed, it will start
a "Cross Zone" timer. If a "Cross Zone" is being timed, it will create an instant alarm. This zone
will bypass automatically, when enabled in segment 1 of location 23.
13
2
INSTANT ENTRY GUARD
This zone creates an instant alarm whenever it is tripped and the stay/instant LED is off. It will
start an entry delay time 2 if it is tripped, provided that the system is armed and the
stay/instant LED is on.
14
2
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED
A trip will start entry delay 1. This zone will bypass when the "Group Bypass" command is
entered at the keypad. Absence of a trip during exit delay will enable the automatic bypass
or instant mode, if so programmed.
15
2
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED
This zone will be instant when the system is armed and no entry or exit delays are being
timed. It is delayed during entry/exit delay times. This zone will bypass when the "Group
Bypass" command is entered at the keypad. This zone will bypass automatically, if enabled in
segment 1 of location 23.
16
2
INSTANT WITH GROUP BYPASS ENABLED
This zone creates an instant alarm whenever it is tripped and the armed LED is on. This zone
will bypass when the "Group Bypass" command is entered at the keypad
17
2
MAINTAINED KEYSWITCH
This zone type will arm the partition or partitions of the control panel where it is resident, as
long as the zone is shorted. This zone type will disarm the partition or partitions of the control
where it is resident, as long as the zone is open. Keyswitch arming will report as user 99.
18
2
ENTRY/EXIT DELAY 1 FORCE ARMABLE
A trip will start entry delay 1. Absence of a trip during exit delay will enable the automatic
bypass or instant mode, if so programmed. This zone is force armable (see feature definitions
pages 5-11).
ENTRY/EXIT DELAY 2 FORCE ARMABLE
19
2
A trip will start entry delay 2. Absence of a trip during exit delay will enable the automatic
bypass or instant mode, if so programmed. This zone is force armable (see feature
definitions, pages 5-11).
20
2
ENTRY/EXIT DELAY 1 WITH CHIME ENABLED
A trip will start entry delay 1. Absence of a trip during exit delay will enable the automatic
bypass or instant mode, if so programmed. When the control panel is disarmed and the
chime mode has been set, this zone will act as a chime zone.
TECHNICAL ALARM, SUPERVISED, AUDIBLE
21
2
Any trip on a technical zone creates an audible alarm, regardless of the arming state of the
control panel. This zone can be bypassed.
TECHNICAL ALARM, SUPERVISED, SILENCE
22
2
Any trip on a silent technical zone creates a silent alarm, regardless of the arming state of
the control panel. Only the transmitter will be activated. This zone can be bypassed.
INTERIOR INSTANT ZONE
23
2
This zone creates an instant alarm whenever it is tripped during the arming state of the
control panel. This zone will bypass automatically, if enabled in segment 1 of location 23, or
when this system is armed in the "Stay" mode.