LED extinguish
This feature will extinguish all the LED's on the keypad, except the "Power" LED, after 60
seconds have elapsed without a keypress. Pressing any numeric key will light up all the LED's
(see location 23 segment 2).
Local programming lockout
This feature will disable programming of all locations, or for specified locations, from the
keypad (see location 21).
Log full report
A report can be sent to the central station when the event log is full (see location 37 segment
4).
Log protection
This feature will prevent a single, non-zone reportable event to fill up the event memory. The
event will only be logged for a maximum of 3 times between closings or code entry. (see
location 37 segment 6).
Lost clock service light
The NX-4 can be programmed to light up the "Service" LED on a LED keypad or give a "Service"
message on a LCD keypad when the internal clock time is invalid due to power loss. On LCD
keypads, if programmed to show the system time, a "Set Clock, *97" message will always be
displayed (see location 37 segment 5).
Manual test
The NX-4 can be programmed to perform a bell and/or communicator test; to do this, enter
[*]-[4]-[4] while the system is in the disarmed state. Each time that [*]-[4]-[4] is entered, a
dynamic battery test will also be performed (see location 37 segment 2).
Night Mode
Applies to NX-1208E / NX-1248E keypads. In this mode, the control panel will bypass all zones
that have the Entry Guard feature enabled. (See location 23 and 111-169)
On board zone disable
The 4 zones on the NX-4 panel can be disabled, in order to obtain a completely wireless alarm
system. A mix of hardwired and wireless zones is also possible (see location 37 segment 5).
Program code
The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] when using a 4-digit code; or,
if the 6-digit option is used, the default is [9]-[7]-[1]-[3]-[0]-[0]. The program code can also be
used as an arm/disarm code. If it is used as an arm/disarm code, and if open/close reports are
sent, the user code will be 255 (see location 43).
Quick arm feature
The NX-4 has a single-button "Quick Arm" feature which can be used to arm the system by
pressing the [Exit] key or the [Stay] key on the keypad. If closing reports are sent, the user code
will be 98 (see location 23 segment 1).
Recent closing
If this option is enabled, the NX-4 will send a "Recent Closing Report" to the central station if
an alarm occurs within 5 minutes after the panel is armed. The user number that was used to
arm the system will also be sent (see location 23 segment 3).
Re-exit
The NX-4 can restart the exit delay for a quick exit without the need to disarm the system; this
is done by pressing the [Exit] key while the system is still armed (= after exit delay has expired).
The re-exit is also logged (see location 23 segment 1).
NX-4-EUR Installation manual
Page 11