Special Formats - GE NX-4-EUR Installation Manual

Networx series
Table of Contents

Advertisement

Special formats

LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (see locations 2, 8, and 14)
Segment 1
Segment 2
Segment 3
Segment 4
NX-4-EUR Installation manual
1 =
On for 1800hz transmit; Off for 1900hz
2 =
On for 2300hz handshake; Off for 1400hz
3 =
On for checksum parity; Off for double round parity
4 =
On for 2 digit event code; Off for 1 digit event code
5 =
On for extended reporting; Off for non-extended reporting
6 =
Reserved
7 =
On for 20 PPS; Off for 10 or 40 PPS
8 =
On for 10 PPS; Off for 20 or 40 PPS
1 =
On for pager format (no handshake required).
2 =
On for 1400/2300 handshake
3 =
Reserved
4 =
Reserved
5 =
On for Contact ID
6 =
On for SIA
7 =
On for 3 digit event code
8 =
On for DTMF
Reserved
Inter-digit time for pulse format:
The inter-digit time is the value programmed on this location, divided by the
pulse-rate (PPS) of the programmed format. This is programmed in a binary
way: in order to program the value "10", options 2 and 4 must be selected,
for value "5", options 1 and 3 must be selected.
Ex: when the value 10 is programmed on segment 4 and a pulse format of
20 PPS is used, the inter-digit time is 10/20 = 0.5 sec.