LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical data)
Location 59 contains the event code for a zone "Trouble" with a 4+2 and 3+1 format. For the
4+2 format, the digit programmed in this location will be sent as the tens digit. As ones digit,
the zone number (1-8) will be reported (e.g. zone 1 = 1, zone 8 = 8).
To report a restore, the restore code of location 56 will be used.
Segment 1
Segment 2-8
LOCATION 60 - SENSOR LOW BATTERY COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments,
numerical data)
Location 60 contains the event code for a zone "Sensor Low Battery" for a 4+2 and 3+1
format. For a 4+2 format, the digit programmed in this location will be sent as the tens digit. As
ones digit, the zone number (1-8) will be reported (e.g. zone 1 = 1, zone 8 = 8).
To report a restore, the restore code of location 56 will be used.
Segment 1
Segment 2-8
LOCATION 61 - SENSOR MISSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 61 contains the event code for a zone "Sensor-missing" for a 4+2 and 3+1 format. For
a 4+2 format, the digit programmed in this location will be sent as the tens digit. As ones digit,
the zone number (1-8) will be reported (e.g. zone 1 = 1, zone 8 = 8).
To report a restore, the restore code of location 56 will be used.
Segment 1
Segment 2-8
LOCATION 62 - DURESS COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical data)
Location 62 contains the tens and ones digits that will be sent for a 4+2 and 3+1 format if the
Duress code is enabled in location 44. Segment 1 contains the tens digit, and segment 2
contains the ones digit.
For a 3+1 format, only the segment 1 digit (tens) will be sent.
LOCATION 63 - KEYPAD AUXILIARY 1 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data)
Location 63 contains the tens and ones digits that will be sent for a 4+2 and 3+1 format if the
keypad "Auxiliary 1" (FIRE) is enabled in the partition feature selection. Segment 1 contains the
tens digit; segment 2 contains the ones digit.
For a 3+1 format, only the segment 1 digit (tens) will be sent.
NX-4-EUR Installation manual
Zones 1-8, "Trouble Code"
Reserved
Zones 1-8, "Sensor Low battery Code"
Reserved
Zones 1-8, "Sensor Missing Code"
Reserved
Page 58