EATURE DEFINITIONS
Abort
If this option is enabled, the NX-4 will wait the programmed number of seconds (0-255) in
location 40 prior to sending an alarm. During this delay time, the "Cancel" LED will flash. To
abort the report, type in a code and press the [Cancel] key. The LED will go out. If the report is
not aborted within the allotted time, the LED will go out when the report is sent. The dialler
delay is programmed at location 40, segment 8. Each zone can be defined as a "dialler delay
zone" by defining the relevant option in segment 3 of the appropriate zone configuration
group (see locations 110-169).
AC fail / low battery report/warning
The NX-4 can be programmed to report an AC failure and/or low battery conditions to the
central station. Low battery will be detected as the battery gets discharged down to 10,5Vdc
and lower. It can also be programmed to sound the keypad immediately when the condition is
detected. The AC failure report/warning can be delayed (see locations 37, 39 and 40).
AC power / low battery sounder alert
If this option is enabled, the NX-4 will beep the keypad sounder upon arming or disarming, if
the AC power is not present or if a low battery has been detected (see location 23, segment 2).
Arm / disarm codes
The NX-4 can have 8 four-digit or six-digit codes to arm/disarm the control panel. All the
codes must have the same number of digits. The factory default for user 1 is [1]-[2]-[3]-[4]
when using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. This code can then be
used to enter the new arm/disarm codes (see location 41).
Automatic arming
If programmed, the NX-4 will Auto Arm at a specified time. At this time, the keypad will start
beeping before the panel arms and this for the amount of time set as warning time (warning
timer). The arming process will be stopped during the warning time if a code is entered on the
keypad or when movement has been detected. The NX-4 will attempt to arm again after the
amount of time set as retry time (retry timer) until the next "opening" time (loc. 52), or until the
system is armed. The panel will not try to re-arm if the retry feature has been disabled. If a
zone is faulted before the warning timer starts and stays faulted when the panel tries to auto-
arm, the zone will automatically be bypassed. The auto arming of a partition can be
programmed so that it is silent. If closing reports are sent, the user code will be 97 (see
locations 23 segment 2, location 40 segment 12 and 13 and location 52-55).
Automatic bypass / instant arming
When this option is enabled, the control panel can automatically bypass interior follower
zones if no exit is detected during the exit delay time. Entry delay zones can also be made
instant (see location 23, segments 1 and 2).
Auto cancel
If enabled, the Cancel and/or Abort features will be automatic (pressing the [Cancel] button is
not required). The Cancel and Abort features, in locations 23 & 40 respectively, must be
enabled to permit this Auto feature to work. For proper operation of these features, "Dialer
Delay" must be enabled in the zone configuration group (see locations 110-169).