LOCATION 124 - CONFIGURATION GROUP 8 ALARM EVENT CODE (1 segment, numerical data)
Location 124 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also
contain the alarm report code for the Robofon format (value 00-99).
LOCATION 125 - CONFIGURATION GROUP 8 CHARACTERISTIC SELECT (5 segments, feature selection data)
Use the "Configuration Group Characteristic Selections" described in Location 111.
LOCATION 126 - CONFIGURATION GROUP 9 ALARM EVENT CODE (1 segment, numerical data)
Location 126 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also
contain the alarm report code for the Robofon format (value 00-99).
LOCATION 127 - CONFIGURATION GROUP 9 CHARACTERISTIC SELECT (5 segments, feature selection data)
Use the "Configuration Group Characteristic Selections" described in Location 111.
LOCATION 128 - CONFIGURATION GROUP 10 ALARM EVENT CODE (1 segment, numerical data)
Location 128 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also
contain the alarm report code for the Robofon format (value 00-99).
LOCATION 129 - CONFIGURATION GROUP 10 CHARACTERISTIC SELECT (5 segments, feature selection data)
Use the "Configuration Group Characteristic Selections" described in Location 111.
LOCATION 130 - CONFIGURATION GROUP 11 ALARM EVENT CODE (1 segment, numerical data)
Location 130 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also
contain the alarm report code for the Robofon format (value 00-99).