Command and Response Table for Matrix Switcher Commands (continued)
Command Function

Test pattern

Enable a test pattern
Disable test patterns
View test pattern selection
Screen saver timeout and status
Set screen saver to go black
immediately
Set screen saver timeout duration
Example:
Set screen saver to never go black
View screen saver timeout duration
View screen saver status
Scaler output rate
Set scaler output rate
Example:
View scaler output rate
Captive screw and Ethernet serial port insertion enables
Enable an input captive screw serial
port insertion
Enable an input Ethernet serial port
insertion
Set all RS-232 input insertions
View input insertion
View all input insertions
Enable an output captive screw
serial port insertion
Enable an output Ethernet serial
port insertion
Set all RS-232 output insertions
View RS-232 output insertion
View all output insertions
NOTE:
X1&
= TP and insertion input number
X1(
= TP (scaled) and insertion output number
X3$
= Duration
X3%
= Screen saver status
X3^
= Scaler output resolution and rate
X3&
= Captive screw or UART
X3#
= Test pattern
SIS Command
Response
(Host to Unit)
(Unit to Host)
EX1(
X3#
}
*
TEST
Test
EX1(
}
*0TEST
Test
EX1(
}
X3#]
TEST
E
X1(
}
T
*0SSAV
SsavT
E
X1(
X3$
}
T
*
SSAV
SsavT
E
}
T3*300SSAV
SsavT3*300
E
X1(
}
T
*501SSAV
SsavT
E
X1(
}
X3$]
T
SSAV
E
X1(
}
X3%]
S
SSAV
EX1(
X3^
}
*
RATE
Rate
E
}
3*75RATE
Rate3*73
EX1(
}
X3^]
RATE
RS-232 Insertion Commands
E
X1&
}
I
*0LRPT
LrptI
E
X1&
}
I
*1LRPT
LrptI
E
X3&
}
I
*LRPT
LrptI
E
X1&
}
X3&]
I
LRPT
E
}
X3&
ILRPT
E
X1(
}
O
*0LRPT
LrptO
E
X1(
}
O
*1LRPT
LrptO
E
X3&
}
O
*LRPT
LrptO
E
X1(
}
X3&]
O
LRPT
E
}
X3&
OLRPT
07
or
08
or
03
04
= Output sync instantly disabled when no active video input is selected
0
through
001
500
= Output sync never times out (default)
501
= Active input detected, timer is not running
0
1
= No active input, timer is running, output sync is still active
= No active input, timer is expired, output sync is disabled.
2
See the table on page 58.
= Captive screw RS-232 insert
0
00
= Disable (default)
= Crop
01
= Alternating pixels
02
= Crosshatch
03
DTP Crosspoint 84 IPCP Series Matrix Switchers • Programming Guide
Additional description
X1(
X3#]
*
X1(
]
*0
X1(
]
Disable sync whenever no input video is
*000
selected.
X1(
X3$]
Blank output
*
]
Blank output 3 after 300 seconds
(5 minutes).
X1(
]
Do not blank output
*501
X1(
X3^]
Set the scaler to output
*
]
Set the scaler to output 720p video at
60 Hz on output 3.
X1&
]
Enable the captive screw serial port
*0
insert on input
Ethernet RS-232 insert.
X1&
]
Enable the Ethernet serial port insert
*1
on input
screw serial port insert.
X3&]
X3&
]
X3&
One
7
8
starting at input 7.
X1(
]
Enable the captive screw serial port
*0
insert on output
Ethernet serial port insert.
X1(
]
Enable the Ethernet serial port insert
*1
on output
captive screw serial port insert.
X3&]
X3&
]
X3&
One
3
4
starting at output 3.
(seconds)
= Ethernet RS-232 insert (UART) (default)
1
04
= Color bars
= Grayscale
05
= Blue mode
06
= Crop and pink noise (Ch. 1/2, 48 Hz, 24-bit)
07
X1(
after
X3$
seconds.
X1(
.
X3^
X1(
on output
.
X1&
. This disables the
X1&
. This disables the captive
for both available inputs,
X1(
. This disables the
X1(
. This disables the
for both available outputs,
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents