4. Replacement and Adjustment
Scanner leading edge and side-to-side registration
4
A: Leading Edge Registration
1. Put the test chart on the exposure glass. Then make a copy from one of the feed stations.
2. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
Standard: 0 ± 2mm for the leading edge registration, 0 ± 2.5mm for the side-to-side registration.
Leading Edge Registration
Side-to-Side Registration

ARDF

ARDF side-to-side, leading edge registration and trailing edge
Use A4/LT paper to make a temporary test chart as shown above.
1. Put the temporary test chart on the ARDF. Then make a copy from one of the feed stations.
2. Check the registration. Check the leading edge and side-to-side registration. Adjust the following SP
modes if necessary.
Standard: 4.2 ± 2 mm for the leading edge registration, 2 ± 1 mm for the side-to-side registration.
Use the following SP modes to adjust if necessary.
SP Code
SP6-006-001
134
CÓPIA NÃO CONTROLADA
What It Does
Side-to-Side Regist: 1st
CÓPIA NÃO CONTROLADA
SP mode
SP4-010-001
SP4-011-001
± 3.0 mm
Adjustment Range