No.
Type
Heating roller warm-up error 1
• The heating roller temperature does not reach 80°C for 20 seconds.
• The center temperature of the heating roller does not reach the ready
temperature for 90 seconds.
542
A
• Dirty or defective thermopile
1. Check if the heating roller thermopile is firmly connected.
2. Replace the thermopile.
No.
Type
Heating roller fusing lamp overheat 1 (software error)
The temperature detected by the heating roller thermopile stays at 230°C for 1
second.
• Defective PSU
• Defective IPU
543
A
• Defective BCU
Related SC code: SC 553
1. Replace the PSU.
2. Replace the IPU.
3. Replace the BCU.