Disassembly and Reassembly
6-13 Main Frame Assembly
1. Before you remove the LSU, you should remove:
- Rear cover (see page 6-3).
- Scanner assembly (see page 6-4).
- Side cover assembly (see page 6-9).
- Exit assembly (see page 6-12).
- LSU (see page 6-15).
- SMPS (see page 6-15).
2. Unplug the all connectors.
6-14 Cover Exit Rear
1. Remove the one screw and cover exit rear, as
shown below.
6-14
3. Remove the six screws and take out the main
frame assembly.
August 2001
Main Frame Ass'y
Cover Exit Rear
WorkCentre Pro 412