Specifications

4-6 Dimension

Machine size (W x D x H)
Machine weight

4-7 Packaging

Power cord
IEEE 1284 cable
USB cable
CD-ROM
Cartridge
Manual

4-8 Environmental Condition

Absolute storage
Recommended operating
condition

4-9 Machine Life

Product life
Product life in pages
Maximum monthly duty cycle
4-4
554.5x 433.9 x 459.1 mm (21.8 x 17 x 18 inches)
About 23 Kg (50.6 pounds) with CRU
1ea (USA standard, ivory)
No
1ea
1ea
Drum CRU 1EA, toner CRU 1EA
1vol.
Temperature-
20 to 40 degrees C (68 to 104 degrees F)
Humidity
10% RH to 95% RH
Temperature
6 to 30 degrees C (43 to 86 degrees F)
Humidity
30% RH to 70% RH
5 years
150,000 printing pages (A4 size, 5% area coverage)
2,500 printing pages (A4 size, 5% area coverage)
August 2001