6. Disassembly and Reassembly
6-1 General Precautions on Disassembly
When you disassemble and reassemble components, you must use extreme care. The close proximity
of cables to moving parts makes proper routing essential. If components are removed, any cables dis-
turbed by the procedure must be restored as close as possible to their original positions. Before
removing any component from the machine, note the cable routing that will be affected.
Whenever servicing the machine, you must perform as follows:
1. Check to verify that documents are not stored in memory.
2. Unplug the power cord.
3. Use a flat and clean surface.
4. Replace only with authorized components.
5. Do not use force to remove or install plastic components.
6. Make sure all components are correctly installed.
6-2 Rear Cover
1. Remove the six screws securing the rear cover.
WorkCentre Pro 412
Launch Issue
WARNING
2. Separate the rear cover from the base frame and
scanner assembly.
August 2001
Disassembly and Reassembly
6-1