Baseboard Management Controller (Bmc) Heart Beat Led; System Configuration Limitations By Intel Xeon Processor E5-2600 V3 And E5-2600 V4 Product Family - Dell PowerEdge C6320 Owner's Manual

Hide thumbs Also See for PowerEdge C6320:
Table of Contents

Advertisement

Table 8. 1600 W AC/1600 W HVDC PSU indicators
Component
AC power indicator

Baseboard Management Controller (BMC) heart beat LED

The system board provides BMC heart beat LED (CR17) for BMC debugs. The BMC heart beat LED is
green. When the system AC power is connected, the LED glows. When BMC firmware is ready, the BMC
heart beat LED blinks.
Figure 11. BMC heart beat LED on the C6320 system board
1.
BMC heart beat LED
System configuration limitations by Intel Xeon processor
E5-2600 v3 and E5-2600 v4 product family
NOTE: Certain system hardware configurations may require reductions in the upper temperature
limits.
NOTE: System performance may be impacted when operating above 30°C or with a fan fault.
18
Indicator
Solid amber
Solid green
Blinking green
Off
Condition
Standby mode with Fan Lock for
15 seconds.
Standby mode with OTP range
Active mode with +12 V DC Fault
Active mode with Fan Lock for 15
seconds.
DC_OK (power good)
Standby mode normal
Unit without AC power

Advertisement

Table of Contents
loading