Dell PowerEdge C6320 Owner's Manual page 52

Hide thumbs Also See for PowerEdge C6320:
Table of Contents

Advertisement

Option
Description
Serial
Selects serial communication devices (Serial Device 1 and Serial Device 2) in BIOS.
Communication
BIOS console redirection can also be enabled and the port address can be
specified. This option is set to Auto by default.
Serial Port
Enables you to set the port address for serial devices. This option is set to Serial
Address
Device 1=COM2, Serial Device 2=COM1 by default.
External Serial
Enables you to associate the External Serial Connector to Serial Device 1, Serial
Connector
Device 2, or the Remote Access Device by using this option.
Failsafe Baud Rate Specifies the failsafe baud rate for console redirection. The BIOS attempts to
determine the baud rate automatically. This failsafe baud rate is used only if the
attempt fails, and the value must not be changed. This option is set to 115200 by
default.
Remote Terminal
Sets the remote console terminal type. This option is set to VT 100/VT 220 by
Type
default.
Redirection After
Enables or disables the BIOS console redirection when the operating system is
Boot
loaded. This option is set to Enabled by default.
Related Links
Serial Communication
Viewing Serial Communication
System Profile Settings
You can use the System Profile Settings screen to enable specific system performance settings such as
power management.
Related Links
System Profile Settings details
System BIOS
Viewing System Profile Settings
52
NOTE: You can use only Serial Device 2 for the Serial Over LAN (SOL) feature.
To use console redirection by SOL, configure the same port address for
console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting
saved in iDRAC. The serial MUX setting can independently be changed in
iDRAC. Loading the BIOS default settings from within the BIOS setup utility
may not always revert the serial MUX setting to the default setting of Serial
Device 1.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use
console redirection by SOL, configure the same port address for console
redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX setting
saved in iDRAC. The serial MUX setting can independently be changed in
iDRAC. Loading the BIOS default settings from within the BIOS setup utility
may not always revert this setting to the default setting of Serial Device 1.