Comelit simplehome Technical Manual page 77

Table of Contents

Advertisement

if the power setpoint is exceeded for the "Delay sending deactivation command" indicated in the advanced settings, the
TIMED CUT-OFF:
module begins to cut off the loads entered on the list.
Immediate cut-off: if the power setpoint is exceeded, the module cuts off all loads entered on the list.
After any type of cut-off the module begins counting down a time period set in the "Time OFF" fi eld, then begins reconnection in the
reverse order to which cut-off took place.
enter a general description of the load. The description is shown in the "Loads" menu on the supervisor.
LOAD DESCRIPTION:
enter the number of the module to which the load in question is connected.
MODULE:
enter the number of the output to which the load in question is connected.
OUTPUT:
enter the anticipated consumption for the entered load. This value is only used during reconnection, to prevent
CONSUMPTION:
continuous connection and disconnection of loads. We recommend entering the average consumption and not the maximum power
value. The value should never be greater than the value set for the disconnection setpoints minus the tolerance and delta values.
enter the time for which the selected load will remain disconnected before an attempt to restore the power is made.
TIME OFF:
set by default to NO, should not be changed if using SimpleProg version 3.2.0 or later. If using previous versions, enter the
NC/NO:
type of connection carried out for the selected load, NO if the load is connected to the NO terminal of a module and NC if the load is
connected to the NC terminal of a module.
If using SimpleProg version 3.2.0 or later, you can set the output connection type when programming the output on the module screen.
If you set NC for the module output and NC on the load control module screen, the two settings will be in confl ict and operation will take
place as though the NO setting has been selected.
Delay sending activation command: enter the time period which must elapse between reconnection of one of the disconnected loads
and the next.