Term.
Function
-
BUS power supply negative
+
BUS power supply +24 Vdc
D
BUS data line
K
Common
V-
Support negative
V+
+24 Vdc support
I8
Input 8
I7
Input 7
I6
Input 6
I5
Input 5
I4
Input 4
I3
Input 3
I2
Input 2
N.B. The module must be programmed via the BUS line, using the SimpleHome/RS232 interface (20022611) and the SimpleProg
programming software.
Specifi cations are subject to change without notice.
28
DIGITAL MODULE
Term.
Function
I1
Input 1
IS
Multiple command (scenario)
NO1
Output 1 – NO contact
C1
Output 1 – Common
NC1
Output 1 – NC contact
NO2
Output 2 – NO contact
C2
Output 2 – Common
NC2
Output 2 – NC contact
NO3
Output 3 – NO contact
C3
Output 3 – Common
NC3
Output 3 – NC contact
NO4
Output 4 – NO contact
C4
Output 4 – Common
green (bus)
red (+)
blue (-)
Term.
NC4
NO5
C5
NC5
NO6
C6
NC6
NO7
C7
NC7
NO8
C8
NC8
Function
Output 4 – NC contact
Output 5 – NO contact
Output 5 – Common
Output 5 – NC contact
Output 6 – NO contact
Output 6 – Common
Output 6 – NC contact
Output 7 – NO contact
Output 7 – Common
Output 7 – NC contact
Output 8 – NO contact
Output 8 – Common
Output 8 – NC contact