HISTORY LOG

The HISTORY LOG is updated with important system information such as, sensor
activation, missing sensors, sensor tampering, and battery notifications for sensors (see
History log Event descriptions below).
Click on the History Log button to open the log in a separate window. History Log can then be
saved to disk or printed out.
History Log (Date, Time, Sensor ID, and Event) is a log of SCOUT system activities. The last
100 events are stored in a circular nonvolatile buffer. When the number of events exceeds 100,
the oldest stored events are overwritten.
History log Event descriptions:
"SCOUT ON"
"SCOUT OFF"
"SCOUT ARMED"
"SCOUT DISARMED"
"SCOUT DATE/TIME SET"
"SCOUT OPERATING ON A/C POWER"
"SCOUT OPERATING ON D/C POWER"
"SCOUT BATTERY LOW"
"SCOUT RESET TO DEFAULT CONFIGURATION"
"USER CONFIG WAS CHANGED THROUGH CONSOLE"
"SENSOR TRIGGERED"
"INPUT RELAY TRIGGERED"
"SENSOR BATTERY LOW"
"SENSOR MISSING"
"SENSOR RETURNED"
"SENSOR RESET"
"SENSOR TAMPERED"
www.response-technologies.com
SCOUT turned on
SCOUT turned off
SCOUT armed and ready for sensor activation
SCOUT disarmed and configurable
SCOUT system clock adjusted by user
SCOUT is running on AC power
SCOUT is running on internal or external battery
SCOUT system battery power is low
SCOUT settings were reset back to default
SCOUT settings were saved using console
SCOUT alarm activated by Sensor ID shown
SCOUT alarm activated using the Input Relay
Sensor battery is low for Sensor ID shown
Sensor ID shown missed the check in at the time
shown
Sensor ID shown checked in after missing a
previous check in
Internal "reset" button was pressed in Sensor ID
shown
Sensor ID shown was tampered