SolarEdge Power Harvesting System Installation Manual
SolarEdge Power Harvesting System Installation Manual

SolarEdge Power Harvesting System Installation Manual

For three phase inverters
Table of Contents

Advertisement

Quick Links

About This Guide
1
SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Power Harvesting System and is the answer not in the manual?

Questions and answers

Summary of Contents for SolarEdge Power Harvesting System

  • Page 1 About This Guide SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5...
  • Page 2: About This Guide

    About This Guide SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers and integrators who are authorized to install and connect a SolarEdge power harvesting system.
  • Page 3: Important Notice

    The material furnished in this document is believed to be accurate and reliable. However, SolarEdge assumes no responsibility for the use of this material. SolarEdge reserves the right to make changes to the material at any time and without notice. You may refer to the SolarEdge web site (www.solaredge.com) for the most updated version.
  • Page 4: Table Of Contents

    Table of Contents SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Table of Contents Handling and Safety Instructions ................6 Support and Contact Information ................8 Chapter 1, Introducing the SolarEdge Power Harvesting System ..9 What is the SolarEdge Power Harvesting Solution? ..........
  • Page 5 Table of Contents SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 4, Commissioning the Installation ........... 37 Commissioning – Workflow .................. 37 Step 1, Activating the System ..................38 Step 2, Pairing Power Optimizers to the Inverter ............39 Step 3, Verifying Proper Operation ................
  • Page 6: Handling And Safety Instructions

    Handling and Safety Instructions SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Handling and Safety Instructions During installation, testing and inspection adherence to the following handling and safety instructions is mandatory. Safety Symbols The following safety symbols are used throughout this document.
  • Page 7 Handling and Safety Instructions SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Instructions WARNING! Do not remove the inverter cover before five minutes have elapsed after disconnecting all sources of power. Only use lockable connectors for DC input.
  • Page 8: Support And Contact Information

    Support and Contact Information SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Support and Contact Information If you have technical problems concerning our products, please contact us: USA & Worldwide Support Line: +1.650.319.8843 Germany: +49.89.4161703-30 France: +33.(0)970.465.662...
  • Page 9: Chapter 1, Introducing The Solaredge Power Harvesting System

    Introducing the SolarEdge Power Harvesting System SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 1 Introducing the SolarEdge Power Harvesting System What is the SolarEdge Power Harvesting Solution? The SolarEdge power harvesting solution maximizes the power output from any type of solar PV installation while reducing the average cost per watt.
  • Page 10: Three Phase Inverter

    Introducing the SolarEdge Power Harvesting System SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 You may refer to the SolarEdge power optimizer datasheets in order to determine which power optimizer is most suitable for you requirements.
  • Page 11: Solaredge Monitoring Portal

    SolarEdge Photovoltaic sites. It provides information about present and past performance of each PV module individually and about the system as a whole. NOTE: You may refer to the SolarEdge Monitoring Portal User Guide for more information about this option.
  • Page 12: Installation Workflow

    SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Installation Workflow The following provides an overview of the workflow for installing and setting up a new SolarEdge site. Most of these procedures can also be used for adding components to an existing SolarEdge site. Connecting Power Optimizers...
  • Page 13: Transport And Storage

    Introducing the SolarEdge Power Harvesting System SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Transport and Storage Three Phase Inverter Transport The Three Phase Inverter should be transported in its original packaging, facing up and without exposing the Three Phase Inverter to unnecessary shocks.
  • Page 14 Introducing the SolarEdge Power Harvesting System SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 For installing the communication option, you may also need the following:  For Ethernet:  RJ45 connectors  CAT5 twisted pair Ethernet cable ...
  • Page 15: Chapter 2, Installing The Power Optimizers

    IMPORTANT SAFETY FEATURE: PV modules with SolarEdge power optimizers are safe. They only carry a low safety voltage before the Three Phase Inverter is turned on. MPORTANT SAFETY FEATURE: As long as the power optimizers are unconnected to the inverter and the inverter is OFF, the power optimizers will output a safe 1V voltage during installation.
  • Page 16 Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 WARNING! Before performing this step, turn OFF the Three Phase Inverter by turning off the ON/OFF switch at the bottom of the inverter and the DC switch of the main circuit board.
  • Page 17: Step 1, Mounting The Power Optimizers

    Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Step 1, Mounting the Power Optimizers NOTE: If you are installing modules with embedded power optimizers, then skip to Step 3, Connecting Power Optimizers in Strings on page 22.
  • Page 18: Step 2, Connecting Each Pv Module To A Power Optimizer

    Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Step 2, Connecting Each PV Module to a Power Optimizer OP250-LV, OP300-MV and OP400- These power optimizers connect to a single PV module via its two inputs (a plus and a minus).
  • Page 19: Pb250-Aob And Pb350-Aob

    Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 PB250-AOB and PB350-AOB These power optimizers connect to a single PV module via its two inputs (a plus and a minus). Input Input Output...
  • Page 20: Pb250-Tfi And Pb350-Tfi

    Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 The following shows the required clearance on the top and bottom of the power optimizer. 1” (2.5 cm) 1” (2.5 cm) Figure 6: Clearance – Side View PB250-TFI and PB350-TFI These power optimizers connect to up to four PV modules via its inputs.
  • Page 21: Connecting Power Optimizers

    Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Connecting Power Optimizers ► To connect these power optimizers to the PV modules: WARNING! Verify that you have identified the inputs and outputs correctly. Do not connect PV modules to power optimizer outputs.
  • Page 22: Step 3, Connecting Power Optimizers In Strings

    Power optimizers must be connected in series in order to construct strings. IMPORTANT NOTE: SolarEdge power optimizers are energized by the PV modules to which they are connected. String length must not be less than 16 power optimizers or the entire string may shut down.
  • Page 23: Verifying Proper Power Optimizer Connection

    Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  The power optimizer output cables are labeled + and – .  Connect the Plus (+) connector of the output wire of the first power optimizer in the string to the Minus (-) connector of the second power optimizer in the string.
  • Page 24 Installing the Power Optimizers SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  If the voltage is lower than the quantity of power optimizers (for example, 9 V when 10 power optimizers are connected), verify whether one or more of the power optimizers are not connected, meaning they were skipped during the string connection process.
  • Page 25: Chapter 3, Installing The Inverter

    Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 3 Installing the Inverter The Three Phase Inverter can be installed either before or after the PV modules and power optimizers have been installed.
  • Page 26: Selecting The Mounting Location

    Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 The inverter serial number is also indicated on the enclosed warranty card. Please provide the serial number when contacting the SolarEdge support line. The serial number is also required when requesting to open a new site in the SolarEdge Monitoring Portal.
  • Page 27: Mounting The Inverter

    Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Mounting the Inverter CAUTION: Make sure that you have read the previous sections in this chapter before starting the mounting process that is described below.
  • Page 28 Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 3 Hang the inverter on the bracket using the screws on the inverter’s top, as shown below: Figure 10: Hanging the Inverter on the Bracket...
  • Page 29: Connecting The Inverter

    Connecting the Inverter Inverter Connection Overview The SolarEdge inverter can be configured in the field for an AC grid, including AC voltage and frequency. If the inverter’s default settings are not suited to the country of the installation site, then please refer to page 71 for a description of how to configure the inverter for the required country.
  • Page 30: Connecting The Three Phase Inverter

    Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 WARNING! Grounding of the DC side is prohibited because the Three Phase Inverter has no transformer. Connecting the Three Phase Inverter Connectors and Cables The following shows the Three Phase Inverter connectors:...
  • Page 31 Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  Provides a configuration, control and management connection to a locally connected PC or laptop, or to an external modem for connection to the SolarEdge Monitoring Portal. You may refer to...
  • Page 32 Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 WARNING! Do not open the cover of the Three Phase Inverter before you turn OFF the ON/OFF switch at the bottom of the inverter and the DC switch of the main circuit board.
  • Page 33 Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 8 Insert the cable through the AC cable gland on the right and connect the wires to the appropriate terminal connectors according to their labels: PE, L1, L2, L3 and N.
  • Page 34: Completing The Three Phase Inverter Installation

    Configuring the Inverter Using the LCD Panel and User Buttons section on page 67. If you plan to use the SolarEdge Monitoring Portal to access SolarEdge site information, you may need to add a physical connection to the proper communication option.
  • Page 35 Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Closing the Cover ► To close the cover: 1 Make sure to reattach the chassis grounding wire, if it was removed. Grounding cable for cover Figure 16: Chassis Grounding Wire Conection 2 Shut the chassis cover and secure it by tightening the screws.
  • Page 36: Residual Current Device

    Installing the Inverter SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Residual Current Device IMPORTANT SAFETY FEATURE: All SolarEdge inverters incorporate a certified internal Residual Current Device (RCD) in order to protect against possible electrocution and fire hazard in case of a malfunction in the PV array, cables or inverter.
  • Page 37: Chapter 4, Commissioning The Installation

    Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 4 Commissioning the Installation Commissioning – Workflow The following workflow describes how to activate the system, commission the installation and verify the proper functioning of the system.
  • Page 38: Step 1, Activating The System

    Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Step 1, Activating the System This section describes how to perform the initial activation stages of the SolarEdge system. These stages are preformed after the inverter and power optimizers have been installed and the power optimizers have been connected to the inverter.
  • Page 39: Step 2, Pairing Power Optimizers To The Inverter

    Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 7 Verify that the Vdc [v] on the LCD panel specifies the DC input voltage, in Volts. There should be a safety voltage of 1 V for each power optimizer connected to the inverter.
  • Page 40 Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 2 Turn on the inverter ON/OFF switch at the bottom of the inverter within five seconds. If you do not turn ON the inverter ON/OFF switch within five seconds, the inverter then exits pairing mode.
  • Page 41: Step 3, Verifying Proper Operation

    Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 During this time, the inverter monitors the grid and verifies correct grid voltage and frequency. This message indicates how many seconds remain until the inverter will be in Production mode. This amount of time is in accordance with the regulations of each country, and is typically between three to five minutes.
  • Page 42: Step 4, Reporting And Monitoring Installation Data

    After a site is opened in the SolarEdge Monitoring Server, you can access all the monitored data about that site. To register a new site, fill in the online form at http:/www.solaredge.com/groups/site-registration.
  • Page 43  See how components are connected to each other. In order to enable the SolarEdge Monitoring Portal to show the strings and physical location of power optimizers, you may first report the physical and logical mapping of the installed power optimizers by mail, email or fax to SolarEdge.
  • Page 44: Providing Installation Information

    Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 The inverter may be connected to the SolarEdge Monitoring Server via a LAN or an external modem connected to the RS232 port. Alternatively, you can connect the inverter to another inverter that is already connected to the server.
  • Page 45 Commissioning the Installation SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  Inverter Serial Number(s) at the Site: Each inverter’s serial number is printed on a sticker on the side of the inverter, on the inverter warranty card and on the inverter box.
  • Page 46: Chapter 5, Replacing And Adding System Components

    Replacing and Adding System Components SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 5 Replacing and Adding System Components Modifying an Existing Installation This section describes how to modify an existing installation that has been operating properly for a while.
  • Page 47 Replacing and Adding System Components SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 3 You can now add or remove power optimizers, add or remove strings, change connections of power optimizers or strings or replace the inverter.
  • Page 48: Replacing The Fans

    Replacing the Fans The inverter has two fans, one is accessible from the outside of the inverter (called Fan 1) and the other is internal and requires a SolarEdge technician to replace it (called Fan 2). Figure 18: Inverter Fan 1...
  • Page 49 Replacing and Adding System Components SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 ► To replace Fan 1: 1 Unscrew the single screw of the fan cover, shown above, using a Philips screw driver. 2 Open the fan door.
  • Page 50: Chapter 6, Setting Up Communication

    Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 6 Setting Up Communication Communication Dataflow The SolarEdge site information can be accessed remotely using the SolarEdge Monitoring Portal, as described in the SolarEdge Monitoring Portal User Guide.
  • Page 51 Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  RS485: page 56, Enables the connection of multiple inverters through the same bus, such that connecting only one inverter to the Internet is sufficient to provide communication services to all the inverters on the bus.
  • Page 52: Creating An Rs232 (Uart) Connection

    This communication option is provided in all inverters by default. It enables you to connect the inverter via modems supplied by SolarEdge. You may refer to the SolarEdge website for a list of the types of modems offered, which includes GSM and WiFi modems. Each modem is provided with its own user manual which should be reviewed.
  • Page 53: Creating An Ethernet (Lan) Connection

    Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 3 Connect the modem to the inverter through the RS232 connector, which is the nine-pin connector on the bottom of the inverter. There is no need to open the inverter cover.
  • Page 54 Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 3 Configure the LAN options under the Communication menu (DHCP [5.2.2] and IP [5.2.1] configurations), as described in the Configuring the Inverter Using the LCD Panel and User Buttons section on page 67.
  • Page 55 Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  Insert the 4 wires into the RJ45 connector. Make sure to use pins 1, 2, 3 and 6. Figure 24: Inserting Wires into the RJ45 Connector ...
  • Page 56: Creating An Rs485 Bus Connection

    Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Creating an RS485 Bus Connection The RS485 option enables you to create a bus of connected inverters (consisting of up to 30 Slave inverters and 1 Master inverter). Using this...
  • Page 57 Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 3 The RS485 bus uses a four-wire telephone cable and a six-wire RJ11 connecter (also known as RJ25). Insert the wire via one of the small cable glands.
  • Page 58 Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 8 The two inverters at the ends of the chain (meaning the first inverter and the last inverter) must be terminated by switching a termination dip-switch inside the inverter to ON.
  • Page 59: Verifying The Connection

    Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Ensure that you select either the Ethernet (5.1.1) or RS232 (5.1.2) option under the Communication  Server menu (5.1), as described in the Configuring the Inverter Using the LCD Panel and User Buttons section on page 67.
  • Page 60: Troubleshooting Communication

    Setting Up Communication SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 5 Verify that the LCD panel displays a window similar to the following: V a c [ v ] V d c [ v ] P a c [ w ] 2 3 0 .
  • Page 61: Chapter 7, Inverter User Interface

    Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Chapter 7 Inverter User Interface Inverter LCD Panel and LEDs The front of the Three Phase Inverter has a small LCD panel and three LEDs, as shown below:...
  • Page 62: Inverter Lcd Panel And User Buttons

    Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  Off: The inverter is not producing power. This may be during Night mode, when the ON/OFF switch is OFF or when an error occurs.
  • Page 63: Normal Operation

    Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  Error messages: In the event of a problem, an error message may be displayed on the LCD panel. You may refer to Appendix A, Errors and Troubleshooting on page 75 and the Configuring the Inverter Using the LCD Panel section on page 67 for more information.
  • Page 64 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  P_OK XX: Indicates a functioning DC line-communication connection to the SolarEdge power optimizers, which indicates that telemetry information was received within the last 10 minutes. XX is the number of paired power optimizers for which telemetries have been received by the inverter in the last two hours.
  • Page 65 The production data is accumulated according to an internal real-time clock. If the inverter is connected to the SolarEdge Monitoring Server, it will automatically set the clock's time. If not, you may use the SolarEdge Configuration Tool to set the clock setting.
  • Page 66 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Fan Health Status Window After you press the inverter’s LCD light button to display the window shown above, you can press it again to display the Fan Health Status window.
  • Page 67: Configuring The Inverter Using The Lcd Panel And User Buttons

    Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Configuring the Inverter Using the LCD Panel and User Buttons After installation of the inverter, a field technician can verify and perform basic configurations of the inverter. This section describes the various LCD messages and possible configurations using the user buttons.
  • Page 68 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 3 The following configuration procedures are performed with the inverter cover open. Open the cover, as described in the Opening the Cover section on page 31.
  • Page 69 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 5 Use the three right-most buttons inside the inverter (the UP-1, Down-2 and Enter-3 buttons), shown above, to type in the following default password: 12312312. Inverter passwords are eight digits long, each digit being between 1 and 3.
  • Page 70 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 The following shows a hierarchical tree of the menu options: C o u n t r y < G E R > L a n g u a g e <...
  • Page 71: Inverter Configuration Menu Options

    Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Each menu option is described below. Use the Up and Down buttons inside the inverter to move the asterisk (*) to the relevant menu option and then press the Enter button to select it.
  • Page 72 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 4 Select the 4. Display option to display the following three options:  4.1 LCD On Time <30>: Specifies the number of seconds that the LCD panel backlight is ON after the LCD light button is pressed.
  • Page 73 Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5  Select options 5.1.1, 5.1.2, 5.1.3 or 5.1.4 to configure the communication method to the SolarEdge Monitoring Portal. Refer to Chapter 6, Setting Up Communication on page 50 for a full description of these communication options: You can also select the 5.1.5 None option if no server communication...
  • Page 74: Configuring The Inverter Using The Solaredge Configuration Tool

    Inverter User Interface SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Configuring the Inverter Using the SolarEdge Configuration Tool Two options are provided for configuring the system:  Using the LCD panel, as described in this guide.
  • Page 75: Appendix A, Errors And Troubleshooting

    Errors and Troubleshooting SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Appendix A Errors and Troubleshooting About This Appendix The inverter LCD panel displays a message when an error occurs. This appendix lists the error messages that may appear on the inverter’s LCD panel, describes their meaning and describes how to troubleshoot each one.
  • Page 76 Errors and Troubleshooting SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 The following table lists the error messages that appear on the inverter and describes how to troubleshoot each one. Error # LCD Message Description Troubleshooting...
  • Page 77 Errors and Troubleshooting SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Error # LCD Message Description Troubleshooting AC Current AC current surge. The If this fault persists:  Surge internal hardware that Check the AC connection to inverter.
  • Page 78 Errors and Troubleshooting SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Error # LCD Message Description Troubleshooting Temperature Over temperature. If the problem persists, then:  Too High Verify that proper ventilation clearance exists around the inverter, as described in the Chassis Clearance section on page 26.
  • Page 79 Errors and Troubleshooting SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Error # LCD Message Description Troubleshooting  Turn off the inverters in the site and verify AC Voltage Grid voltage is above the limit AC grid voltage.
  • Page 80 Errors and Troubleshooting SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Error # LCD Message Description Troubleshooting Islanding AC grid voltage When AC voltage returns the inverter should malfunctions. The inverter restart after some time (time depends on has shut off due to islanding.
  • Page 81: Appendix B, Technical Specifications

    Technical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Appendix B Technical Specifications About This Appendix The table in this appendix provides the technical specifications of the SolarEdge system components. Three Phase Inverter SE7k SE8k SE9k SE10k SE12.5k...
  • Page 82 Technical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 SE7k SE8k SE9k SE10k SE12.5k Input Recommended Maximum DC Power (Module STC) 7700 8800 9900 11000 13000 Transformer-less, Ungrounded Maximum Input Voltage Nominal DC Input Voltage Maximum Input Current 15.5...
  • Page 83: Op250-Lv, Op300-Mv And Op400-Mv

    Technical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 OP250-LV, OP300-MV and OP400-MV OP250-LV OP300-MV/OP400-MV Input Rated Input DC Power 300/400 Absolute Maximum Input Voltage 5 – 55 5 – 75 MPPT Operating Range Maximum Input Current...
  • Page 84: Pb250-Aob And Pb350-Aob

    Technical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 OP250-LV OP300-MV/OP400-MV Installation Specifications Dimensions (W x L x H) 120 x 130 x3 7 / 4.72 x 5.11 x 1.45 mm / in Weight 450 / 1.0...
  • Page 85: Pb250-Tfi And Pb350-Tfi Power Optimizer

    Technical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 PV System Design 8 – 25 String Limitations - EU, 1ph System Modules 16 – 50 String Limitations - EU, 3ph System Modules 8 – 25...
  • Page 86 Technical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 CEC Weighted Efficiency 97.7 Inductive Lightning Protection 1 / 3 m / ft Nighttime Power Consumption Output During Operation (Inverter is Operating) Maximum Output Current Operating Output Voltage...
  • Page 87: Appendix C, Power Optimizer Mechanical Specifications

    Power Optimizer Mechanical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 Appendix C Power Optimizer Mechanical Specifications About This Appendix This appendix presents the mechanical specifications for the SolarEdge power optimizers. Use M8 screws and washers to secure the power optimizer units to the racking.
  • Page 88: Op250-Lv, Op300-Mv, Op400-Mv Power Optimizers

    Power Optimizer Mechanical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 OP250-LV, OP300-MV, OP400-MV Power Optimizers The following figure shows the mechanical specifications for the OP250- LV, OP300-MV, OP400-MV, power optimizers: Figure 31: Power Optimizer Mechanical Specifications...
  • Page 89: Pb250-Aob And Pb350-Aob Power Optimizers

    Power Optimizer Mechanical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 PB250-AOB and PB350-AOB Power Optimizers The following figure shows the mechanical specifications for the PB250- AOB and PB350-AOB power optimizers: Figure 32: PB250-AOB and PB350-AOB power optimizer Mechanical...
  • Page 90: Pb250-Tfi And Pb350-Tfi Power Optimizer

    Power Optimizer Mechanical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5 PB250-TFI and PB350-TFI Power Optimizer The following figure shows the mechanical specifications for the PB250- TFI and PB350-TFI power optimizers: Figure 33: PB250-TFI and PB350-TFI Power Optimizer Mechanical...
  • Page 91 Power Optimizer Mechanical Specifications SolarEdge Installation Guide for Three Phase Inverters – EU – Version 1.5...

Table of Contents